Siemens 6AV6651-7KA01-3AA4 - S7-1200 + KTP400 Basic Starter Kit 6AV6651-7KA01-3AA4 사용자 설명서

제품 코드
6AV6651-7KA01-3AA4
다운로드
페이지 364
Motion control is easy 
 
10.6 Operation of motion control for S7-1200 
 
Easy Book 
250
 
Manual, 03/2014, A5E02486774-AF 
Parameter 
Description 
Reference point switch  
(Active and passive homing) 
 
Active homing: Select whether the axis is to be referenced on the left or right side 
of the reference point switch. Depending on the start position of the axis and the 
configuration of the homing parameters, the reference point approach sequence 
can differ from the diagram in the configuration window. 
 
Passive homing: With passive homing, the traversing motions for purposes of 
homing must be implemented by the user via motion commands. The side of the 
reference point switch on which homing occurs depends on the following factors: 
–  "Approach direction" configuration 
–  "Reference point switch" configuration 
–  Current travel direction during passive homing 
Approach velocity  
(Active homing only) 
Specify the velocity at which the reference point switch is to be searched for during 
the reference point approach.  
Limit values (independent of the selected user unit):  
Start/stop velocity ≤ approach velocity ≤ maximum velocity 
Reduced velocity  
(Active homing only) 
Specify the velocity at which the axis approaches the reference point switch for 
homing. 
Limit values (independent of the selected user unit):  
Start/stop velocity ≤ reduced velocity ≤ maximum velocity 
Home position offset  
(Active homing only) 
If the desired reference position deviates from the position of the reference point 
switch, the home position offset can be specified in this field.  
If the value does not equal 0, the axis executes the following actions following 
homing at the reference point switch: 
1.  Move the axis at reduced velocity by the value of the home position offset. 
2.  When the position of the home position offset is reached, the axis position is set 
to the absolute reference position. The absolute reference position is specified via 
parameter "Position" of motion control instruction "MC_Home". 
Limit values (independent of the selected user unit):  
-1.0e12 ≤ home position offset ≤ 1.0e12 
 
Table 10- 38  Factors that affect homing 
Influencing factors: 
Result: 
Configuration 
Approach direction 
Configuration 
Reference point switch 
Current travel direction 
Homing on 
Reference point switch 
Positive 
"Left (negative) side" 
Positive direction 
Left 
Negative direction 
Right 
Positive 
"Right (positive) side" 
Positive direction 
Right 
Negative direction 
Left 
Negative 
"Left (negative) side" 
Positive direction 
Right 
Negative direction 
Left 
Negative 
"Right (positive) side" 
Positive direction 
Left 
Negative direction 
Right