Bunn FMD-1* 사용자 매뉴얼

다운로드
페이지 30
29
SERVICE (cont.)
14. Refer to Fig. 29  when reconnecting the wires to the
tank heater.
TANK HEATER (cont.)
FIG. 29 TANK HEATER TERMINALS
P1218
FIG. 30 TANK HEATER SWITCH
TANK HEATER SWITCH
P1505
Location:
The tank heater switch located inside the dis-
penser on the upper right of the front panel.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect the black wire from the power source
and the black wire from the thermostat.
3. With the switch in the “ON” lower position check
for continuity between the center and the upper
terminal. With the switch in the “OFF” upper posi-
tion no continuity should be present between
center and upper terminals.
If continuity is present as described, the tank heater
“ON/OFF” switch is operating properly.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Remove the switch mounting nut on the front of
the front panel.
2. Remove switch with wires attached from the rear
of the front panel.
3. Remove the wires from the switch terminals and
discard switch.
4. Connect the wires to the new switch, refer to fig.
31.
5. Push new switch through hole in the front panel
and secure with face nut.
FIG. 31 TANK HEATER SWITCH TERMINALS
P1219
BLK to Control
Thermostat
BLK from Main
Harness
WHI or RED to
Main Harness
BLK to Limit
Thermostat
28364 041598