15 
The default is no preamble.  To select a preamble, scan up to 15 characters from 
the "FULL ASCII MENU" on the back of the RF Laser Setup Menu, and then 
scan SET when you're done.  To return to the no preamble setting, scan Clear 
here instead of scanning SET or any characters from the FULL ASCII MENU. 
 
You can trim 1-15 leading characters from bar code codes by scanning a  ~ 
(tilde -- ASCII 126) followed by a single digit, 1 through F, as part of the 
Preamble. (Bar codes that are shorter than the amount-to-trim are transmitted 
with no trimming.)  Consider the examples in the following table to 
understand how trimming works: 
 
Bar Code Data Preamble Data 
Transmitted 
123 XYZ 
XYZ123 
12345678 ~3XYZ 
XYZ45678 
12345678 ~9 12345678 
12345 ~A 12345 
123456 
~5 
                              6 
 
You can also trim selectively by bar code type. For example, you can trim 2 
characters from Code 39 and a different amount from other bar code outputs. This 
is done by using the bar code ID character in conjunction with the tilde (~).  A 
preamble of ~b2~c1 says trim 2 characters from the front of Code 39 output and 
trim 1 character from the front of UPC-A. Refer to the Code 128 parameter on 
page 12 for a list of the ID character associated with each bar code type. 
 
A final use of the Preamble/Postamble is to enter a minimum/maximum length 
check for bar code data read.  Use the Preamble or Postamble by entering 
|nnmm where "|" is ASCII 124,  "nn" is the two digit minimum to be read and 
"mm" is the two digit maximum to be read. 
 
Postamble 
"Postamble" refers to a user-specified data string transmitted at the end of each 
bar code.  For instance, if you specify the postamble @@ and read data of 
123456, "123456@@" would be transmitted to your computer.   
 
The default is no postamble.  To select a postamble, scan up to 15 characters 
from the "FULL ASCII MENU" on the back of the Reader Setup Menu, and 
then scan SET when you're done.  To return to the no postamble setting, scan 
CLEAR here instead of scanning SET or any characters from the FULL 
ASCII MENU. 
 
You can trim 1-15 trailing characters from bar code codes by scanning a  ~ (tilde 
-- ASCII 126) followed by a single hex digit, 1 through F. (Bar codes which are 
shorter than the amount-to-trim are transmitted without trimming.)  Consider the 
examples in the following table to understand the options of the Postamble: