Illuminance Meter
T-10A series
Compatible with new, next-generation light sources including PWM-controlled sources.
For simple but accurate illuminance measurements. Makes creating illuminance
measurement systems such as multi-point measurement systems easy!
T-10A
T-10MA/T-10W
S
A/T-10W
L
A
<Mini receptor >
<Standard receptor>
T-10MA
(Cord length: 1 m)
Conforms to JIS AA Class
and DIN class B
Enables illuminance
measurements of small areas.
Can be used for illuminance
measurements in narrow spaces
where the standard receptor won't fit.
It can also be easily installed on
various kinds of equipment or jigs
for measuring light levels such as
illumination.
T-10W
S
A
(Cord length: 5 m)
T-10W
L
A
(Cord length: 10 m)
Conforms to JIS requirements
for special illuminance meters
The mini receptor and cord are both
waterproof, so they can be used for
measurements in water.
They can be used for illuminance
control for fishery-related applications
(such as fish farming, etc.) or for
measuring outdoor illuminance on
rainy days.
T-10A
Conforms to JIS AA Class
and DIN class B
Can be used for general
measurements of illuminance.
Custom order
Waterproof
Reliable, worry-free illuminance meters that
conform to JIS AA Class and DIN Class B
Illuminance Meters T-10A and T-10MA conform to Class AA of JIS
C 1609-1: 2006 "Illuminance meters Part 1: General measuring
instruments" and DIN 5032 Part 7 Class-B " Photometry;
classification of illuminance meters and luminance meters"
requirements to provide high-accuracy, high-reliability, worry-free
measurements.
Illuminance meters conforming to these standards are required for
measurements of general illumination light sources, white LED lamps
for illumination, etc. in a variety of industrial fields.
Compatible with PWM-controlled lighting. Enables
measurements of next-generation light sources.
Conventional illuminance meters often cannot accurately
measure PWM-controlled light sources, but the T-10A series
of illuminance meters can be used to accurately measure
even such light sources.
Removable receptor
The receptor and main body
can be detached from each
other and then connected
using a LAN cable, making it
easy to install as part of an
inspection system.
z
9-point example: Projectors, etc.
●
z
5-point example: Architectural lighting, etc.
z
25-point example: Street lighting, etc.
z
Government testing organizations
z
Research/inspection at illumination
equipment makers
z
Maintenance at factories, offices, hospitals,
etc.
z
Illuminance control of security lighting,
street lighting, etc.
z
Checking light sources for construction
z
Lighting control at LED-lit factory farms
z
As sensor for equipment measuring total
flux or light-
distribution
characteristics,
etc.
M a i n F e a t u r e s
Multi-point illuminance measuring system
Main applications
Receptor
diffuser
window:
Ø 25 mm
Receptor
diffuser
window:
Ø 14 mm
Cross-section A
illuminance (lx)
Horizontal distance (m)
H
ei
gh
t
(m)
0
0
1
1
2
2
3
3
4
-1
-2
-3
300
100
50
10
30
5
Easy, inexpensive multi-point measurement
(2 to 30 points).
Illuminance distribution of a projector etc. can be easily
measured with a single instrument and several receptors.
illuminance Measurement Trio
Illuminance Meter T-10A series
Illuminance Meter T-10A series