3 Counter module
Wiring of the counter module
Connect the incremental encoder to the counter input
The counter module has an input circuit that permits the connec-
tion of various types of incremental encoder. The encoder that is 
connected can have a differential output or an open-collector 
output.  The following examples illustrate the various connection 
options.
Two incremental encoders
Figure 22:
Connection for 2 incremental encoders (example)
COUNTER
RESET
CH2
CH1
A(+)
A(–)
B(+)
B(–)
M(+)
M(–)
V
in
A
A(–)
V
in
B
B(–)
V
in
M
M(–)
Z(–)
Z(+)
B(–)
B(+)
A(–)
A(+)
a
A
B
Z
a
24 V 
H
0 V