Ericsson EDACS LBI-39077 사용자 설명서

다운로드
페이지 66
GETTING STARTED
LBI-39077
13
Figure 5 shows a sample Update menu with the By type category selected. When this category is first selected, the System
config
 operation is automatically selected. Selecting another operation will change the information in the HELP window.
EDACS GTI Configurator/Database Manager V1.3                 (SUPERVISOR mode)
 UPDATE MENU: ì  Global    By type  ì
                        ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                        ³ System config   ³
                        ³ Telco config    ³
                        ³ DID numbers     ³
                        ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
ÉÍHELPÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»ÉÍSTATUSÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
ºSelect item with arrow keys and       ºº                                     º
ºENTER or capital letter. ESC to quit  ººConnecting to system....             º
º                                      ººRequesting unit type....             º
ºUpdate System Config allows the SystemººConnected to GTI system!             º
ºConfiguration data to be sent to all  ººReady to process commands            º
ºunits at the selected system.         ºº                                     º
º                                      ºº                                     º
º                                      ºº                                     º
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
Still connected to System
Figure 5 - Sample Update Menu with the By type Category Selected
The By type category of operations continues to require communication with a GTI unit in the system via a local or remote
data link, to send and/or receive information about the system’s configuration or performance. This category includes the
following specific operations:
• 
The System config operation is used to send just the system configuration data in the GTI database to the GTI units
in the selected system.
• 
The Telco config operation is used to send just the telco configuration data in the GTI database to the GTI units in
the selected system.
• 
The DID numbers operation is used to send just the DID number data in the GTI database to the GTI units in the
selected system.
If you get the message like "No bus master, cannot clone data" this means that the unit you updated cannot perform the
automatic cloning function to the other GTIs on the Subscriber Bus. If you are in your shop working with one unit, then
ignore the message. If you have dialed your system, then either the subscriber master is inoperative, a subscriber bus cable is
faulty, or you have not installed the Master Card into one of the units (refer to the ELI System Manual).