Carrier Access AB II 사용자 설명서

다운로드
페이지 66
Analog Ports
8-5
Loop-reverse-battery signaling 
Network-provided reverse-battery signaling
E&M signaling
Customer-installation-provided loop-start supervision.
8.2.1 Update Interval
The Update Interval window graphically represents the user-selected interval for updating the infor-
mation on this screen. Set the interval by dragging the slide control up and down with your mouse 
cursor. To turn off updates, put the slide control at its lowest position.
Figure 8-2: Update Intervals
The interpretation of the signaling bits for D4 framing are as follows:
D4 (SF) Framing Format
See the legend at the end of this table for explanations of abbreviations.
Signaling Type
State
Receive (Network-
to-Subscriber) 
Transmit 
(Subscriber-to-
Network) 
Rx
Tx
A
B
A
B
Loop-start 
signaling (FXO-
FXS)
LCF
LO  (on  hook)
0
1
0
1
Ringing
LC  (off  hook)
0
0
1
1
Loop-start 
signaling with 
RLCF (FXO-FXS)
LCF
LO  (on  hook)
0
1
0
1
RLCF
LC (off hook)
0
1/0
1
1
LCFO
1
1