Fabric OS Administrator’s Guide
201
53-1001763-02
FIPS Support
9
FIPS Support
Federal information processing standards (FIPS) specify the security standards needed to satisfy a 
cryptographic module utilized within a security system for protecting sensitive information in the 
computer and telecommunication systems. For more information about FIPS, refer to 
The v6.4.0 firmware is digitally signed using the OpenSSL utility to provide FIPS support.To use the 
digitally signed software, you must configure the switch to enable Signed Firmwaredownload. If it is 
not enabled then the firmware download process ignores the firmware signature and work as 
before. 
If Signed Firmwaredownload is enabled, and if the validation succeeds, the firmware download 
process proceeds normally. If the firmware is not signed or if the signature validation fails, 
firmwareDownload fails. 
To enable or disable FIPS, refer to 
.
Public and Private Key Management
For signed firmware, Brocade uses RSA with 1024-bit length key pairs, a private key and a public 
key. The private key is used to sign the firmware files when the firmware is generated. The public 
key is packaged in an RPM-package as part of the firmware, and is downloaded to the switch. After 
it is downloaded, it can be used to validate the firmware to be downloaded next time when you run 
the firmwareDownload command.
The public key file on the switch contains only one public key. It is only able to validate firmware 
signed using one corresponding private key. If the private key changes in future releases, you need 
to change the public key on the switch by one of the following methods:
By using the firmwareDownload command. When a new firmware is downloaded, 
firmwareDownload always replaces the public key file on the switch with what is in the new 
firmware. This allows you to have planned firmware key changes.
By using the firmwareKeyUpdate command. This command retrieves a specified public key file 
from a specific server location and replaces the one on the switch. So for easy access, the 
information regarding firmware versions and their corresponding public key files should be 
documented in the release notes or stored in a known location in the Brocade website. This 
command allows the customer to handle unplanned firmware key changes.
NOTE
If FIPS is enabled, all logins should be done through SSH or direct serial and the transfer protocol 
should be SCP.
Updating the firmwarekey
1. Log in to the switch as admin.
2. Type the firmwareKeyUpdate command and respond to the prompts.
The firmwareDownload Command
As mentioned previously, the public key file will need to be packaged, installed, and run on your 
switch before downloading a signed firmware.