Limitations and restrictions of Traffic Isolation Zoning
12
TI over FCR is not backward compatible with Fabric OS v6.0.x or earlier. The -1 in the 
domain,index entries causes issues to legacy switches in a zone merge. Firmware downgrade 
is prevented if TI over FCR zones exist.
Additional configuration rules for enhanced TI zones
Enhanced TI zones (ETIZ) have the following additional configuration rules:
Enhanced TI zones are supported only on the following platforms: Brocade 300, 5100, 5300, 
5410, 5424, 5450, 5460, 5470, 5480, 7800, 8000, VA-40FC, DCX, DCX-4S, and Brocade 
Encryption Switch.
Enhanced TI zones are not supported on the Brocade 4100, 4900, 5000, 7500, 7500E, 7600, 
and 48000.
Enhanced TI zones are supported only if every switch in the fabric is ETIZ capable. A switch is 
ETIZ capable if it meets the following qualifications:
-
The switch must be one of the supported platforms, as listed above.
-
The switch must be running Fabric OS v6.4.0 or later.
If the fabric contains a switch running an earlier version of Fabric OS, you cannot create an 
enhanced TI zone. You cannot merge a downlevel switch into a fabric containing enhanced TI 
zones, and you cannot merge a switch with enhanced TI zones defined into a fabric containing 
switches that do not support ETIZ.
NOTE
FC router domains and EOS switches are excluded from the ETIZ platform restrictions. You can 
create enhanced TI zones with these switches in the fabric.
Trunking with TI zones
Note the following if you implement trunking and TI zones:
To include a trunk group in a TI zone, you must include all ports of the trunk in the TI zone. 
Trunked ISL ports cannot be members of more than one TI zone.
Limitations and restrictions of Traffic Isolation Zoning
The following are limitations of TI zones:
For switches running Fabric OS 6.1.0 or later, a maximum of 255 TI zones can be created in 
one fabric. For switches running Fabric OS 6.0.x, no more than 239 TI zones should be 
created.
A fabric merge resulting in greater than the maximum allowed TI zones results in merge failure 
and the fabrics are segmented.
A TI zone can be created using D,I (Domain, Index) notation only, except for TI zones in a 
backbone fabric, which use port WWNs. See 
 fo
information about TI zones in a backbone fabric.
To include a trunk group in a TI zone, you must include all ports of the trunk in the TI zone.