Brocade Communications Systems 53-1001763-02 사용자 설명서

다운로드
페이지 586
316
Fabric OS Administrator’s Guide
53-1001763-02
E_Port authentication between Fabric OS and M-EOS switches
14
 
TABLE 63
Switch authentication policy when connected to an M-EOS dumb switch
Because the M-EOS switch does not know about authentication, there is never an authenticated 
connection made. However, the E_Port is established when the Fabric OS switch is configured in 
Passive or Off states. The cases where the connection fails are when the Fabric OS switch is 
configured as On or Passive. This is because these states require the authentication of the E_Ports 
to respond to authentication requests. See 
 on page 312 for the Fabric OS mode 
descriptions. The Passive and Off cases never exchange authentication frames, and therefore 
come up as normal E_Ports.
Authentication of EX_Port, VE_Port, and VEX_Port connections
VE_Ports run authentication the same as E_Ports; for information on authenticating E_Ports, see 
EX_Ports and VEX_Ports both run authentication in Passive mode. This means these ports will not 
initiate authentication, but they will respond to authentication requests initiated by the connecting 
switch. Changing the switch authentication policy mode does not affect the authentication function 
of EX_Ports; they remain in Passive mode.
If you connect an M-EOS switch in On mode to an EX_Port set to McDATA Open Fabric mode or 
McDATA Fabric mode, authentication should work the same as connecting an M-EOS switch to a 
Fabric OS switch in Passive mode. The authenticated connection is successful if the M-EOS switch 
has the correct secret for the Fabric OS switch and the Fabric OS switch has the correct secret for 
the M-EOS switch. 
NOTE
The EX_Port’s secret is configured on the Fabric OS switch the same way it is configured for an 
E_Port. However, the front domain WWN should be used to install the shared secret on the E_Port 
side. 
M-EOS switches do not support VE_Port or VEX_Port connections; any configurations with these 
port types are Fabric OS-only configurations. However, both VE and VEX_Ports support running in 
McDATA interop mode.
Fabric OS
Passive
Active
On
Off
M-EOS
Disabled
Yes
Connected without 
any authentication 
(Fabric builds 
normally). 
No
E_Port does not connect 
(Authentication Rejected). 
When the Fabric OS switch 
generates the reject, it 
disables the Fabric OS port. 
When the M-EOS switch 
generates the reject, it goes 
to an invalid attachment 
state.
No
E_Port does not connect 
(Authentication Rejected). 
When the Fabric OS switch 
generates the reject, it 
disables the Fabric OS port. 
When the M-EOS switch 
generates the reject, it goes 
to an invalid attachment 
state.
Yes
Connected 
without any 
authentication 
(Fabric builds 
normally).