Brocade Communications Systems 53-1001763-02 사용자 설명서

다운로드
페이지 586
Fabric OS Administrator’s Guide
321
53-1001763-02
FCR SANtegrity
14
TABLE 66
VEX_Port-to-VE_Port authentication policy with correct secrets
TABLE 67
VEX_ Port-to-VE_Port authentication policy when secrets are not correct
Authentication of VEX_Port-to-VEX_Port connections
Connecting VEX_Ports to each other is not relevant for authentication, because both ports will 
always operate in Passive mode. Because ports in Passive mode do not initiate authentication, 
VEX_Ports cannot have an authenticated connection between them.
FCR SANtegrity 
FC-FC Routing (FCR) SANtegrity is supported for Fabric Binding when EX_Ports are attached to a 
McDATA edge switch. Fabric Binding lets you configure a Fabric Binding Membership list that each 
switch in a fabric can use to validate between it and its neighbor. McDATA SANtegrity Fabric Binding 
uses a list made up of domain ID and WWN pairs and implies the use of Insistent Domain IDs. 
When Fabric Binding is enabled, a Fabric Binding check is performed each time a link is enabled to 
ensure that the switches can connect. If the binding check fails, the McDATA port goes to an invalid 
attachment state and the EX_Port disables itself.
NOTE
After a Fabric Binding check failure between a McDATA E_Port and an EX_Port, the current M-EOS 
implementation requires you to disable the M-EOS port and then re-enable it before the link can 
come up again. Enabling just the EX_Port does not always allow the link to come up again.
Fabric OS switch 
VEX_Port-to-VE_Port
Passive Active
On
Off
Passive
Yes
Connected without 
any authentication 
(Fabric builds 
normally). 
Yes!
Connected with 
two-way 
authentication; both 
sides of the 
connection perform 
Authentication (Fabric 
builds normally).
Yes!
Connected with 
two-way 
authentication; both 
sides of the 
connection perform 
Authentication (Fabric 
builds normally).
Yes
Connected without 
any authentication 
(Fabric builds 
normally). 
Fabric OS switch
VEX_Port-to-VE_Port
Passive Active
On
Off
Passive
Yes
Connected without 
any authentication 
(Fabric builds 
normally). 
No
E_Port does not 
connect 
(Authentication 
Rejected). When the 
Fabric OS switch 
generates the reject, 
it disables the Fabric 
OS port. When the 
M-EOS switch 
generates the reject, 
it goes to an invalid 
attachment state.
No
E_Port does not 
connect 
(Authentication 
Rejected). When the 
Fabric OS switch 
generates the reject, 
it disables the Fabric 
OS port. When the 
M-EOS switch 
generates the reject, 
it goes to an invalid 
attachment state.
Yes
Connected 
without any 
authentication 
(Fabric builds 
normally).