Brocade Communications Systems 53-1001763-02 사용자 설명서

다운로드
페이지 586
Fabric OS Administrator’s Guide
433
53-1001763-02
F_Port masterless trunking
19
The DCX-4S supports trunk groups with up to eight ports. The trunking groups are based on the 
user port number with contiguous eight ports as one group, for example 0-7, 8-15, and 16-23.
F_Port trunking considerations for Virtual Fabrics
Following are the F_Port trunking considerations for virtual fabrics:
If a port is enabled for F_Port trunking, then you must disable the configuration before you can 
move a port from the logical switch.
If the user bound area for a port is configured using the portAddress command, then the port 
cannot be configured as an F_Port trunk port. You must explicitly remove the user bound area 
before enabling F_Port trunking.
If you swap a port using the portSwap command, then you must undo the port swap before 
enabling F_Port trunking.
The Port WWN format in a Virtual Fabric is 2z:zz:xx:xx:xx:xx:xx:xx. The z:zz is the logical port 
number, for example, the logical port 450 will be 1:c2. The xx:xx:xx:xx:xx:xx is based on the 
logical fabric’s WWN, for example, if the logical fabric’s WWN is 10:00:00:05:1e:39:fa:f3, and 
logical port number is 450, then the Port WWN of the F_Port trunk will be 21:c2: 
00:05:1e:39:fa:f3.
F_Port trunks are not allowed on the base switch.
NOTE
A base switch is a logical switch that is used to communicate among different logical switches. 
F_Port trunks enabled on Fabric OS v6.2.0 are non-disruptive to Fabric v6.4.0.
If F_Port trunking is enabled on some ports in the default switch, and you disable Virtual 
Fabrics, all of the F_Port trunking information is lost. 
The ports in a trunk group can be partitioned into different logical switches, therefore all of the 
ports in an F_Port trunk must belong to a single trunk group of ports on the platform and must 
also belong to the same logical switch.
F_Port masterless trunking 
On edge switches, the masterless trunking feature is called F_Port masterless trunking because it 
trunks F_Ports on the switches running in Access Gateway (AG) mode. If the switch is in AG mode, 
the trunk ports must be F_Ports that are connected to N_Ports. The ISL trunking feature supports 
N_Port connections for edge switches running Fabric OS 6.2.0 or later.
This feature keeps F_Ports from becoming disabled when they are mapped to an N_Port on a 
switch in Access Gateway mode. With F_Port trunking, any link within a trunk can go offline or 
become disabled, but the trunk remains fully functional and there are no reconfiguration 
requirements.
The following table describes the PWWN format for F_Port and N_Port trunk ports.