Fabric OS Administrator’s Guide
53-1001763-02
LSAN zone configuration
21
fcrPhyDevShow shows the physical devices in the LSAN.
switch:admin> fcrphydevshow
        Device           WWN            Physical
        Exists                            PID
       in Fabric
       -----------------------------------------
           75 10:00:00:00:c9:2b:c9:0c c70000
           2  50:05:07:61:00:5b:62:ed 0100ef
           2  50:05:07:61:00:5b:62:ed 0100e8
 Total devices displayed: 3
fcrProxyDevShow shows the proxy devices in the LSAN.
switch:admin> fcrproxydevshow 
  Proxy           WWN             Proxy      Device   Physical    State
 Created                           PID       Exists     PID
in Fabric                                   in Fabric
----------------------------------------------------------------------------
    75   50:05:07:61:00:5b:62:ed  01f001       2       0100e8   Imported
    2    10:00:00:00:c9:2b:c9:0c  02f000       75      c70000   Imported
Total devices displayed: 2
On the FC router, the host and Target A are imported, because both are defined by 
lsan_zone_fabric2 and lsan_zone_fabric75. However, target B is defined by lsan_zone_fabric75 
and is not imported because lsan_zone_fabric2 does not allow it.
When a PLOGI, PDISC, or ADISC arrives at the FC router, the SID and DID of the frame are checked. 
If they are LSAN-zoned at both SID and DID edge fabrics, the frame is forwarded to the DID. If they 
are not zoned, only the PLOGI is dropped; for the remaining frames zoning enforcement takes place 
in the edge fabrics.
Setting the maximum LSAN count
You can set the maximum number of LSAN zones, or LSAN count, that can be configured on the 
edge fabrics. By default, the maximum LSAN count is set to 3000. You can increase the maximum 
LSAN count to 5000 without disabling the switch.
The maximum number of LSAN devices supported is 10000 (this includes both physical and proxy 
devices). If you have 3000 LSAN zones but have not exceeded the 10000 device limit, you can 
increase the LSAN count to 5000.
All FC routers in the same backbone fabric should have the same maximum LSAN count defined, to 
prevent the FC routers from running into indefinite state. Asymmetric LSAN configurations due to 
different maximum LSAN counts could lead to different devices being imported on different FC 
routers.
1. Enter the fcrlsancount command with no parameters to display the current LSAN limit.
switch:admin> fcrlsancount 
LSAN Zone Limit 3000
2. Enter the fcrlsancount command and specify the new LSAN zone limit.
switch:admin> fcrlsancount 5000
LSAN Zone Limit 5000
For information on how to display the maximum allowed and currently used LSAN zones and 
devices, see