Fabric OS Administrator’s Guide
53-1001763-02
Internal Ethernet devices
B
Internal Ethernet devices
During the switch initialization process, a new internal Ethernet device is created. The devices 
created are inbd0 and inbd1. Ethernet device inbd0 is used to communicate through GE port 1 and 
inbd1 is used to communicate through GE port 0. These new Ethernet interfaces are internal only 
and are not accessible from outside the switch. They are used strictly for communicating IP packets 
between the CP and the GE port processor.
 shows the Inband Management process. During initialization, the hardware addresses 
for inbd0 and inbd1 are initialized to create a hardware address that is unique for each Ethernet 
interface. After the Ethernet device is initialized, it is enabled for use. At this point, the Ethernet 
device can start sending and receiving Ethernet frames.
FIGURE 79
Inband Management process
The NAT IP table is loaded and automatically configured on startup.The source address NAT is 
configured on the Inband Management interfaces to use the address of the CP management 
interface (eth0). The switch automatically uses the IP address of the CP management interface for 
the source address NAT for the new Inband Management interfaces, so no additional configuration 
is required.
IP address and routing management
The CP and GE port processor Ethernet interfaces must have IP addresses associated with them. 
By default, there will be no IP addresses associated with these new Ethernet interfaces. To manage 
the IP addresses for the CP and GE port processor Ethernet interfaces, use the portCfg 
inbandmgmt command on the CP. 
Specifying the portCfg inbandmgmt command with the
 
routeadd or routedel options adds and 
deletes route entries to and from the CP and the GE port processor routing tables. IP addresses 
must be configured for both devices prior to configuring any routes. When configuring the routes for 
the CP, the GE port processor inband device address for that GE port is used instead of the