OPERATION
3.  Move the fuel shutoff valve to the ON position (see 
Figure 27).
Figure 27 – Fuel Shutoff Valve in the ON Position
NOTICE
This generator is equipped with an automatic 
choke for starting. This system is always on and 
cannot be turned off. Do not attempt to make 
adjustments to the automatic choke or any other 
carburetor adjustments. Tampering with the 
automatic choke system may void your warranty. 
See an authorized Westinghouse service center for 
more information.
4.  Turn the engine control switch to the START 
position until the engine starts. Once the engine 
starts, release the engine control switch; the switch 
will automatically move into the ON position (see 
Figure 28)
.
Figure 28 – Engine Control Switch
NOTICE
Failure to release the engine control switch once 
the engine starts could result in damage to the 
generator. 
Never turn the engine control switch to the START 
position while the engine is running; this could 
damage the generator.
OTE:
N
If the engine fails to start after 5 seconds, 
release the engine control switch. Let the 
generator sit idle for 15 seconds and then 
repeat step 4. If the cranking speed drops 
after each unsuccessful attempt, then the 
battery may not be adequately charged. 
OTE:
N
The generator is equipped with a battery 
charging feature. Once the engine is 
running, a small charge is supplied to 
the battery via the battery cables and will 
slowly recharge the battery.