High End Systems Technobeam 사용자 설명서

다운로드
페이지 173
Technobeam
®
 User Manual
Overview
5-3
Overview
The Technobeam LAD makes it easy for you to position the mirror 
during daylight or high ambient light conditions.  This in turn allows 
you the additional flexibility to set up or verify mirror preset positions 
in conditions that would otherwise make positioning difficult or 
impossible.
Recommended Laser Operation
The most effective and efficient way to use the laser aiming device is 
with the fixture’s lamp off and dim flags (shutter) closed.  There are 
three reasons for this:
The higher the temperature, the shorter the life of the laser aiming 
device.  Keeping the lamp off minimizes the temperature inside the 
fixture, extending the life of the laser.
The higher the temperature, the less bright the laser will be.  If the 
fixture operates (with the lamp on) at 40°C (104°F) for example, 
laser power will be decreased by about 25%.  
Technobeam was designed so the laser light can exit the fixture 
with the dim flags (shutters) closed or completely open.  At certain 
intermediate dim flag positions, the laser light might be partially 
blocked.
Intended Audience
Only qualified and trained employees approved by a laser safety 
officer should be assigned to install, adjust and operate the laser 
equipment.
Using the Laser Aiming Device
You can control the laser using either the fixture’s onboard programs, 
the Technobeam LCD controller, or any DMX 512-compliant controller 
as shown in the section titled “Controlling the Laser” on page 5-5.
The laser exits the fixture through the same aperture as the light beam, 
as shown in Figure 5-1.  Technobeam was designed so that the laser is 
visible if the dim flags are completely closed or open.