Precautions
Technobeam
®
 User Manual
Precautions
This section lists precautions you must follow anytime you are 
servicing the fixture.  
WARNINGS
Before performing any service or 
maintenance, make note of the following:
(1) Hot lamp may be an explosion hazard.  Do 
not open for 5 minutes after switching off.  
Wear eye and hand protection when re-
lamping.
(2) Equipment surfaces may reach 
temperatures up to 70° C (158° F).  Allow 5 
minutes for cooling before handling.
(3) Disconnect power before re-lamping or 
servicing.
(4) Replace fuses with the specified type and 
rating 
only.
(5) Never look directly at the lamp while 
lamp is on.
(6) The procedures in this chapter are 
intended to assist qualified service 
personnel because Technobeam fixtures are 
to be serviced by qualified service 
personnel 
only.
Replacing Fuses
This section explains how to replace any of the three fuses located on 
the fixture’s circuit board.  Make note of the warnings in the section 
titled “Precautions” on page 6-2.
Note
All fuses are 5 mm x 20 mm.
Table 6-1.  Replacement Fuses
Fuse
Amps
Volts
Fuse Type
F1
4.0 A
125 V
Fast Blow Only
F2
2.5 A
250 V
Fast Blow Only
F3 
6.3A
250 V
Slow Blow Only