High End Systems Technobeam 사용자 설명서

다운로드
페이지 173
Technobeam
®
 User Manual
Optional Accessories
1-5
Environmental Specifications
Maximum ambient temperature (T
a
):
50° C (122° F)
Maximum exterior surface temperature:
70° C (158° F)
Minimum distance to flammable objects:
1.0 m (3.28 ft)
Minimum distance to lighted object:
1.0 m (3.28 ft)
DMX Data Cabling
DMX data cables:
  Belden
®
 9841 or equivalent (meets 
specifications for EIA RS-485 applications) with characteristics 
listed below:
2-conductor, twisted pair plus a shield
maximum capacitance between conductors - 30 pF/ft.
maximum capacitance between conductor & shield - 55 pF/ft.
maximum resistance of 20 
Ω
/1000 ft.
nominal impedance 100–140 
Ω
22–24 AWG with insulation having a dielectric rating of 300 
volts or higher
DMX data connectors:
  3-pin male and female XLR connectors
DMX data terminators:
  Male XLR connector with 120 ohm 
terminator between pins 2 and 3 (see Figure 2-4 on page 2-6)
Controllers
Technobeam may be controlled with any of the following:
The  Status  Cue
®
 lighting system
The Technobeam LCD controller 
Another DMX 512-compatible controller  
Optional Accessories
Table 1-1 below shows the optional accessories for Technobeam, 
available from your High End Systems
®
 dealer/distributor:
Table 1-1.  Optional Accessories
Name
Part Number
Optional lens sets
Call*
Replacement MSD 250-2 lamp
Call*
Custom color wheel dichroic filters
Call*
LithoPatterns
Call*