High End Systems Technobeam 사용자 설명서
Technobeam
®
User Manual
Powering On the Fixture
2-3
Status LEDs
Technobeam fixtures have three status LEDs located on the access
door, as shown in Figure 2-2:
door, as shown in Figure 2-2:
Figure 2-2. Location of the three status LEDs on the fixture’s access door.
Table 2-1 describes the three status LEDs:
If the LED states indicate a problem, see the section titled
“Troubleshooting” on page 2-20.
“Troubleshooting” on page 2-20.
* - The Receive LED will not be ON unless the fixture is connected to a
DMX 512 link with a working controller. If you have already connected
DMX 512 link with a working controller. If you have already connected
Table 2-1. Status LEDs
LED name
State
Problem
Indication?
Description
Motor
solid red
No
The motors are receiving adequate
voltage.
voltage.
OFF
Yes
Fuse or power failure. See below.
Transmit
OFF
Not necessarily* No data is being transmitted.
flickering yellow
No
A software crossload is taking place.
solid yellow
Yes
†
Software or hardware failure.
Receive
OFF
Not necessarily* No data is being received.
flickering green
No
Fixture is receiving data.
Door retaining screw
Access door