High End Systems Technobeam 사용자 설명서

다운로드
페이지 173
2-18
Upgrading Software
Technobeam
®
 User Manual
For example, in Table 2-4, if you assigned fixture number 2 (F 02) to the 
Technobeam set to reduced protocol, it would assume that all other 
fixtures on the link are also using 14 DMX channels, so it will 
erroneously try to receive channel 15 as the first channel in its channel 
range.  This would create channel overlapping because fixture number 
1 (Technobeam iris protocol) is already using channel 15 in its 18-
channel range.  
In this example, to prevent overlapping channels, you must assign 
fixture number 3 (F 03) to the Technobeam (reduced protocol), even 
though it is physically the second fixture on the DMX link.  While this 
would prevent overlapping channels, it would result in wasted 
channels that could not be used (see Table 2-4).    
 
Therefore, if you choose to assign fixture numbers to different types of 
devices (and/or protocols) on the same DMX link, refer to “Fixture 
Number to DMX Start Channel” on page A-16
, which shows the channel 
ranges reserved for each Technobeam fixture type.  This table will help 
you determine the next available DMX start channel/fixture number for 
successive Technobeam fixtures on the link.  
Upgrading Software
There are three ways you can upgrade the software (fixture-specific 
operational code) to Technobeam fixtures attached to a DMX link:
Uploading software from Status Cue.  
You will need to obtain 
updated software from High End Systems or a dealer/distributor.  
Consult the Status Cue User Manual for instructions on uploading.
Table 2-4.  Example of Wasted DMX Channels
Fixture 
location 
on the 
link
Fixture name
Number of DMX 
channels used 
per fixture
Fixture number: 
DMX channel range 
used (to prevent 
overlapping)
Resulting 
channels 
wasted
First
Technobeam
(iris protocol)
18 channels
F 01 : 01-18
Second
Technobeam
(reduced protocol)
14 channels
F 03 : 29-42
11 channels 
wasted 
(19-29)
Third
Technobeam
(iris protocol)
18 channels
F 04 : 55-72
13 channels 
wasted 
(43-54)
Fourth
Technobeam
(reduced protocol)
14 channels
F 07 : 85-98
12 channels 
wasted
(73-84)