Note:
1. During an alarm the reader and the request-to-exit are enabled.
2. To cancel the alarm go to Menu 03 in programming and enter 00.
Events
Quand l’alarme est commandée (forced door open, door ajar or lockout alarm) the following
messsages are printed on the event report   «Alarm» and «Alarm end» with the day and hour of
the event.
F.  Memory
The memory unit on the PROMI 1000 can be removed. The time outputs, the schedules, the holi-
day periods, the badges, the Pin codes and the events are stored in the memory unit.
All the data on the memory
G.  Anti pass – back
To start the anti passback mode go to menu 08. The PROMI 1000 must used as an exit unit and the
remote reader as the entry reader.
It is important to present the badge on the entry reader and on the exit reader. The access is
granted only when the badge was presented on the exit reader.
H.  Setting Date and Hour
The PROMI 1000 has a buit-in clock calender with time and date. The clock must always be
powered by the 12V power supply or the 3V CR1225 battery.
The battery is used only in case of power failure. 
                   Event                            Date       Heure
  Mode
   
Alarm                                           25.09.03     17.38     2
   Alarm cleared                               25.09.03     17.44     2