Instructions for the installer
11
4.1
Instructions for wall mounting (primary system)
The anti-tip brackets are to be attached to the rear wall as shown. The
height of bracket location from the floor is determined after the range legs
have been adjusted to the installation height as shown in the installation
instructions and the range has been leveled.
1 Level the range
using the
adjustable
leveling legs.
2 From the floor,
measure the height
of the notch found
on the bracket. This
notch corresponds
to the centerline of
the holes for the
screws that will
fasten the brackets
to the wall.
3 Attach the two anti-tip brackets to the wall
using an appropriate fastener (for example,
screws appropriate for the type of wall).
Respect the heights indicated in the figures
using the appliance’s dimensions as a guide.
(Type of screw recommended 
1
/
4
”).