Gaggenau AL400721 브로셔
214
Ventilation appliances
A W 400 190
Stainless steel
Width 90 cm
Air extraction/recirculation
Width 90 cm
Air extraction/recirculation
A W 400 120
Stainless steel
Width 120 cm
Air extraction/recirculation
Width 120 cm
Air extraction/recirculation
A W 400 150
Stainless steel
Width 150 cm
Air extraction/recirculation
Width 150 cm
Air extraction/recirculation
A W 402 190
Stainless steel
Width 90 cm
Air extraction with remote fan unit
AR 400/401
Motorless
Width 90 cm
Air extraction with remote fan unit
AR 400/401
Motorless
A W 402 120
Stainless steel
Width 120 cm
Air extraction with remote fan unit
AR 400/401
Motorless
Width 120 cm
Air extraction with remote fan unit
AR 400/401
Motorless
A W 402 150
Stainless steel
Width 150 cm
Air extraction with remote fan unit
AR 400/401
Motorless
Width 150 cm
Air extraction with remote fan unit
AR 400/401
Motorless
Necessary installation accessories
A D 010 012
A D 010 012
Exhaust air duct stainless steel, for
ceiling heights 2.25 m - 2.64 m
ceiling heights 2.25 m - 2.64 m
A D 010 022
Exhaust air duct stainless steel, for
ceiling heights 2.64 m - 3.02 m
ceiling heights 2.64 m - 3.02 m
Air recirculation duct for ceiling
heigths including air flow in the duct
(order activated charcoal filter
separately)
A D 010 112
heigths including air flow in the duct
(order activated charcoal filter
separately)
A D 010 112
Recirculating air duct stainless steel
for ceiling heights 2.36 m - 2.64 m
for ceiling heights 2.36 m - 2.64 m
A D 010 122
Recirculating air duct stainless steel
for ceiling heights 2.64 m - 3.02 m
for ceiling heights 2.64 m - 3.02 m
A D 010 392
Ceiling collar for air ducts
Stainless steel
Stainless steel
Special accessories
K F 001 010
K F 001 010
Activated charcoal filter
Side duct, special ducts
made to measure.
Please enquire about price.
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Wall-mounted hood
A W 400/A W 402
– Classic design, high performance
– Highly efficient patented rim
extraction
– Planed and easy to clean underside
with covered filters
– Air extraction or recirculation
system
– Dimmable Soft-Light
Output
Performance and noise level, output
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
Appliance width 90 cm
Air extraction:
520 / 740 m³/h.
57 / 66 dB (A) re 1 pW.
43 / 52 dB (A) re 20 μPa.
Air recirculation:
400 / 470 m³/h.
69 / 71 dB (A) re 1 pW.
55 / 57 dB (A) re 20 μPa.
Air extraction:
520 / 740 m³/h.
57 / 66 dB (A) re 1 pW.
43 / 52 dB (A) re 20 μPa.
Air recirculation:
400 / 470 m³/h.
69 / 71 dB (A) re 1 pW.
55 / 57 dB (A) re 20 μPa.
Appliance width 120 cm
Air extraction:
580 / 800 m³/h.
59 / 70 dB (A) re 1 pW.
45 / 56 dB (A) re 20 μPa.
Air recirculation:
420 / 490 m³/h.
71 / 75 dB (A) re 1 pW.
57 / 61 dB (A) re 20 μPa.
Air extraction:
580 / 800 m³/h.
59 / 70 dB (A) re 1 pW.
45 / 56 dB (A) re 20 μPa.
Air recirculation:
420 / 490 m³/h.
71 / 75 dB (A) re 1 pW.
57 / 61 dB (A) re 20 μPa.
Appliance width 150 cm
Air extraction:
580 / 800 m³/h.
59 / 70 dB (A) re 1 pW.
45 / 56 dB (A) re 20 μPa.
Air recirculation:
420 / 490 m³/h.
71 / 75 dB (A) re 1 pW.
57 / 61 dB (A) re 20 μPa.
Air extraction:
580 / 800 m³/h.
59 / 70 dB (A) re 1 pW.
45 / 56 dB (A) re 20 μPa.
Air recirculation:
420 / 490 m³/h.
71 / 75 dB (A) re 1 pW.
57 / 61 dB (A) re 20 μPa.
Output ventilation appliances
motorless.
See table page 246/247 .
motorless.
See table page 246/247 .
Features
3 electronically controlled output
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Rim extraction filter, dishwasher-safe.
Dimmable halogen Soft-Light 3 x 20/
3 x 20/4 x 20/3 x 20/3 x 20/3 x 20 W .
Glass cover.
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Rim extraction filter, dishwasher-safe.
Dimmable halogen Soft-Light 3 x 20/
3 x 20/4 x 20/3 x 20/3 x 20/3 x 20 W .
Glass cover.
Planning notes
For calculating the exhaust air line go
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
A large drop in output and significantly
increased noise can be expected in the
air recirculation mode in the case of
ventilation hoods with a very high air
output.
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
A large drop in output and significantly
increased noise can be expected in the
air recirculation mode in the case of
ventilation hoods with a very high air
output.
Vario cooktops with intensive
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
Clearance above gas appliances min.
70 cm.
Clearance above electric appliances
min. 60 cm.
Side outlet possible no lower than
55 cm from the bottom edge of the
hood (pipe middle).
Fit the socket concealed behind
ventilation duct.
Weight 24 – 40 kg.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4016,
ground and brushed IIIC.
The dimensions of the air ducts refer to
a distance of 1.60 m from the floor to
the bottom edge of the hood.
Convert for other installation heights:
Worktop height + minimum clearance
+ hood with duct.
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
Clearance above gas appliances min.
70 cm.
Clearance above electric appliances
min. 60 cm.
Side outlet possible no lower than
55 cm from the bottom edge of the
hood (pipe middle).
Fit the socket concealed behind
ventilation duct.
Weight 24 – 40 kg.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4016,
ground and brushed IIIC.
The dimensions of the air ducts refer to
a distance of 1.60 m from the floor to
the bottom edge of the hood.
Convert for other installation heights:
Worktop height + minimum clearance
+ hood with duct.
Connection
Total connected load 275/320/340 W .
Connecting cable 1.5 m with plug.
Plug pair for connecting cable for
motorless hood included with the
remote fan unit AR.
Connecting cable 1.5 m with plug.
Plug pair for connecting cable for
motorless hood included with the
remote fan unit AR.