To ensure quiet operation of ENERGY STAR qualified 
inline and remote fans, each fan shall be installed using 
sound attenuation techniques appropriate for the 
installation. For bathroom and general ventilation 
applications, at least 8 feet of insulated flexible duct shall 
be installed between the exhaust or supply grille(s) and the 
fan. For kitchen range hood remote ventilation 
applications, where metal duct is generally required by 
code, a metal sound attenuator shall be installed between 
the range hood and the fan. 
Causes for damages 
CAUTION 
Risk of damage due to corrosion. Always turn 
appliance on when cooking to avoid condensation 
buildup. Condensation can lead to corrosion 
damages. 
Always replace defective bulbs immediately to avoid an 
overload of the remaining bulbs. 
Risk of damage due to ingress of humidity into the 
electronic circuitry. Never clean operator controls with a 
wet cloth. 
Surface damage due to incorrect cleaning. Clean stainless 
steel surfaces in the grind direction only. Do not use any 
stainless steel cleaners for operator controls.  
Never use strong or abrasive cleaning agents, since they 
can cause surface damage.  
Risk of damage from condensation back flow. Install 
exhaust vent at a slight downward slope away from the 
appliance (1° slope). 
Protecting the environment 
Unpack the appliance and dispose of the packaging in line 
with environmental requirements. 
General notes 
Fan operation 
Note: Ventilation may not exit through an already 
operational smoke or exhaust chimney, nor a duct used for 
ventilating furnace installation areas. 
If the ventilation is intended to pass through a smoke or
exhaust that is not in operation, the responsible area 
heating inspector must give approval. 
If the ventilation passes through an external wall, use a
telescope wall sleeve.
Ventilation line 
Note: The manufacturer does not assume any warranty 
for complaints attributable to the pipe section. 
The device achieves its optimum performance by
means of a short, straight exhaust air pipe and as large
a pipe diameter as possible.
The optimum extraction performance is not achieved
and fan noise is increased if exhaust air pipes are long
and rough and if there is a large number of pipe bends
or diameters less than 5 15/ia" (150 mm).
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Round pipes 
An inner diameter of 5 
15
/
16
" (150 mm), but at least 4 
3
/
4
(120 mm), is recommended.  
Flat ducts 
The inner cross-section must correspond to the diameter 
of the round pipes. 
Ø 5 
15
/
16
" (150 mm) approx. 27 
1
/
2
 sq in (177 cm
2
)  
Ø 4 
3
/
4
" (120 mm) approx. 17 
1
/
2
 sq in (113 cm
2
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.