- 7 -
 
Fig. 2.3 TOP EXHAUST GASKET 
(LOCATED ON THE COOLING UNIT) 
•  Cut a rectangular inside opening at the rear of the cabinet with the 1/4” 
clearance inwards to the width and height of the cooling unit. By not going 
through, leave 1/2” lip inside at the wall to place the gaskets (see Fig. 2.2). 
•  If top exhaust, cut another rectangular opening at the top of the cabinet to 
the length and width of the top exhaust (see Fig.2.2). 
•  Make 2 holes at the ceiling to install the 1/4 inside diameter wood thread 
inserts (see Fig.2.2). 
•  Place the gaskets (1) on the gasket lips (see Fig 2.1). 
•  If top exhaust, place another gaskets along the top exhaust at the top of 
the cooling unit (see Fig.2.3). 
•  Place the cooling unit to a flat and stable place.  
•  Then move it on the top of the wine rack temporally.  
•  Move the cooling unit towards the mounting sides and push to press the 
gaskets.  
•  Fasten the 2 brackets and use 7/16” wrench to tighten the 2 screws (see 
Fig 2.1). 
•  If top exhaust, install another top exhaust grille at the top of the cabinet.  
•  Plug the cooling unit in receptacle. 
•  Plug the wine cabinet. 
 
NOTE: DO NOT INSTALL ANY DUCTS ONTO THE SUPPLY, INTAKE ANY 
EXHAUST. 
 
3. Electrical Cord 
 
•  Because of potential safety hazards under a certain condition, we strongly 
recommend against the use of an extension cord. However, if you still 
elect to use an extension cord, it is absolutely necessary that it will be a 
UL LISTED 3-wire grounding type appliance extension cord having a 3-
blade grounding plug and a 3-slot receptacle that will plug into the 
appliance. The marked rating of the extension cord shall be 115 V, 15 A.