f. 
Refrigerant low or leaking 
 
g.  Capillary tube blockage 
f.  Check for current and sealed 
system leakage 
g.  Check for low side pressure  
11.Water leak 
a. High humidity 
b.  Air leak in wine cellar 
c.  Evaporator air flow restriction 
 
d. Water passages restricted 
e.  Drip tray leak 
a.  Use drain line  
b.  Check for any air leak 
c. Check air flow or air TD crossing 
evaporator  
d.  Clean the drip tray 
e.  No water overflow but leak 
12.Circuit 
tripping 
a.  Incorrect fuse or breaker 
b. Incorrect 
wirings 
c. Failed 
components 
 
a.  Check for proper fuse or breaker 
b.  Check for wirings and connections 
c.  Call service  
 
13.Noisy 
operation 
a.  Mounting area not firm 
b. Loose 
parts 
 
 
c.  Compressor overloaded due to 
high ambient temperatures or 
airflow restriction 
d. Malfunctioning 
components 
 
a.  Add support to improve installation 
b.  Check fan blades, bearings, cabinet 
washers, tubing contact and loose 
screws. 
c.  Check for airflow blockage 
 
 
d.  Call service for checking internal 
loose, inadequate lubrication and 
incorrect wirings