Instructions for the installer 
 
 
24 
 
  2 INSTALLATION 
 
   
 
 
2.1 Electrical 
connection 
 
 Check that mains voltage and power cable ratings are as per the 
indications provided on the label attached to the oven door frame. 
This label must never be removed. 
 
   
 
  It is obligatory for the electrical system to be grounded according to the
methods required by safety rules. 
 
 
   
 
  If a plug and socket connection is being used make sure that the plug
and socket are compatible. Avoid use of adapters and shunts as these
could cause overheating and risk of burns. 
 
   
 
  If a fixed connection is being used fit power line with an omnipolar circuit
breaker with a contact opening gap equal to or greater than 3 mm in an 
easily accessible position in proximity to the oven. 
 
   
 
  Remove rear cover by loosening relevant screws to gain access to the
terminal strip. Secure power cable to oven by means of the appropriate 
fitting. 
 
   
 
 
 
 
If the power cable is replaced, the wire 
section on the new cable must not be 
less than 1.5 mm
2
(3 x 1.5 cable), 
keeping in mind that the end to be 
connected to the hob must have the 
ground wire (yellow-green) longer by 
at least 20 mm.  
 
 
 
 
   
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by non-observance of the above prescriptions or by 
interference with any part of the appliance.