Error Code 75-1
FRU/Action in Sequence:
Ÿ
DC-DC & BATT board
 
Ÿ
System board
Error Code 89-250 to 89-294
FRU/Action in Sequence:
Ÿ
Reload BIOS default setting
 
Ÿ
CPU card
 
Ÿ
System board
Error Code 170-1 to 175-198
FRU/Action in Sequence:
 
Ÿ
System board
Error Code
Test(s)
Message
75-1
AC
CHARGER
AC Charger not sup-
ported
Error Code
Test(s)
Message
89-250
CPU
Math coprocessor
89-266
CPU
Registers
MMX
89-278
CPU
Arithmetics
89-282
CPU
Logical ops
89-286
CPU
String ops
89-294
CPU
Exceptions
Error Code
Test(s)
Message
170-1
LM80/LM81
Chip not detected
(iFailNoLm80=1)
170-27
LM80/LM81
All interrupts masked
170-198
LM80/LM81
Chip not detected
(iFailNoLm80=0)
170-250
LM80/LM81
Interrupt condition
detected
175-1
LM75/
Max1617/
FAN
Chip not detected
(iFailNoLm80=1)
Fan test not supported
No fan detected
175-198
LM75/
Max1617
Chip not detected
(iFailNoLm80=0)
   
ThinkPad 390X / i 1700 HMM