Vermont Casting DVT38S2 사용자 설명서

다운로드
페이지 40
17
Chateau™ Decorative Gas Appliance
20009543
Vertical Through-the-Roof 
Applications
Use of Restrictor Plate 
for Vertical Venting Application
The primary purpose for the vent restrictor is to regain 
flame height under certain venting conditions as 
outlined below.
NOTE: The joints of the inner pipe (flue pipe) must be 
taped with 550°F or higher temperature metal adhesive 
tape that meets the requirements of F.A.R. 25.853(a). 
High temperature sealant milpack or stove cement 
of 550°F or higher could be used instead. The joints 
of The outer pipe (fresh air pipe) must be taped with 
315°F or higher temperature metal adhesive tape or the 
use of high temperature milpack or stove cement would 
be applicable. When using the unitized 30°, 45° or 90° 
elbows, apply 1/4” bead of high temperature, 550°F or 
higher, sealant (milpack or stove cement) to the joint of 
the inner pipe (flue pipe) and the straight section as it is 
impossible to be taped. The outer pipe must be taped 
with 315°F high temperature metal adhesive tape for 
proper sealing.
For vertically venting either propane or natural gas 
units, with vertical vent heights of 12’ (3.7m) or greater, 
(measured from the top of the flue collar) the restrictor 
plate as supplied with this unit should be used. (Fig. 
28) Refer to Page 21, Figure 37 for restrictor plate 
installation.
X
FP1461
Fig. 28  Restrictor plate use in straight up installation.
2.  Install the two (2) brackets, using the sheet metal 
screws, at the  bottom right and left corners of the 
unit. (Fig. 27)
FP1481
install brackets
4/04
Bracket
Sheet Metal 
Screws
FP1481
Fig. 27  Use sheet metal screws to attach brackets to existing 
holes under glass frame assembly.
3.  Set the glass frame assembly provided with your kit 
in front of the glass frame assembly on the unit (the 
outside side).
4.  Have the machine screws provided with the kit within 
reach.
5.  Unfasten the two (2) machine screws that secure the 
glass frame assembly to the unit and discard. Slide 
the glass frame assembly provided with the kit over 
the surround around the glass frame assembly on 
the side and top.
  WARNING: The glass frame assembly provided with 
the unit must be left in place for proper operation. 
Failure to do so could cause property damage and 
malfunction of the unit.
6.  Fasten the two (2) long machine screws at the top 
through the two (2) glass frame assemblies and fas-
ten the two (2) short machine screws at the bottom 
right and left corner into the bracket installed earlier.