Chateau™ Decorative Gas Appliance
20009543
Accessories
Remote Controls
Optional remote control units are available to control 
different functions of the appliance.
  Model 
Function(s) Controlled
  RC1 
On/ Off
  RC2 
On/Off and Temperature
  IMTFK 
Wall-mounted Thermostat Control 
   
(For use in Canada ONLY)
Full Surround Mantel
The Chateau Full Surround has been designed for 
installation with the DVT38S2 Chateau fireplace. 
Hinged face panels on the surround allow access to the 
fireplace control box and gas valve. Accurate framing of 
the fireplace is critical to proper installation.
Refer to the instructions supplied with the Surround for 
complete details.
CAUTION: If you are framing with the plan to use the 
surround mantel mentioned above, it is extremely 
critical to meet the dimensions provided, especially  if 
the mantel is not available at the time of framing.
NOTE: In the event the mantel is not available at the 
time of framing the unit/valve box, you must make 
the spacer on the left side of the valve box in order to 
access the valve box door through the opening in the 
mantel.
  Full Surround Mantel Models:
   
CHFN049S
   
CHFWC49S
   
CHFPR49S
Position the DVT38S2 fireplace in the rough opening. 
Measure up from the floor 45¹⁄₄” and attach the control box 
spacer (G) to the inside of the wall stud. Attach a fram-
ing cross piece between the studs, above the control box 
spacer. Fit the control box tight against the spacer (G) and 
the frame piece above. Fasten the control box to the frame 
piece with 1¹⁄₄” screws through the holes in the top of the 
control box.
FP1479
full surround mantel
framing
4/04
CL
48���"
(1222 mm)
11/16"
(17 mm)
24���"
(613 mm)
45���"
(1149 mm)
Critical 
Dimension
3“ (76 mm)
3 x 12 Control box Spacer ‘G’
Framing 
Cross 
Piece
FP1479
Fig. 63  Chateau Full Surround Mantel framing.
of Glass
(Not Unit)
NOTE: The vertical dimension is shown from the floor 
where the fireplace sits. If a marble hearth extension, or 
other type of material is used, the vertical framing will 
increase by the thickness of the material used to ac-
commodate the height difference when the mantel sits 
on the hearth extension.
CAUTION: If you are framing with the plan to use the 
CHFN0495, CHWC495, CHFPR495 surround mantel, 
it is extremely critical to meet the dimensions provided, 
especially if the mantel is not available at the time of 
framing. A framing stud is allowed to be placed on 
the inside of the 6” (152 mm) standoff on the side 
of the unit where the conduit is located to meet the 
24
¹⁄₈” ( 613 mm) critical dimension from the center 
of the unit.
The unit is certified with a 3” (76 mm) standoff (to 
combustible) on the side of the unit where the conduit is 
located, therefore; it is permissible to locate stud on the 
inside of the standoff at 3” (76 mm) from the body of the 
unit. (Fig. 63)
NOTE: The 6” (152 mm) standoff is sent out with the 
unit for the purpose of making the glass symmetrical 
with respect to the overall width of the unit.