Rinnai RHFE-750ETRA 사용자 설명서

다운로드
페이지 40
 
            Rinnai Corporation RHFE-750ETRA 
 
Application 
Vented gas fireplace heater; Inbuilt only; for residential installation, commer-
cial setting, or manufactured home; not designed for installation in a solid-fuel 
burning fireplace 
General Description 
Inbuilt convector, glass and steel fronted, ceramic log space heater with 
forced convection and power flue system 
Operation 
Push button electronic / remote control  
Gas Connection 
Flex line is 3/8 inch flare nut;  
ball valve is 1/2 inch female x 3/8 inch flare  
Gas Control 
Electronic 
Burners Flame 
burners 
Temperature Control 
Electronic thermostat 
Logs Ceramic 
Ignition System 
Electronic spark ignition 
Flue System 
The flue must be terminated to atmosphere.  Only flue components listed with 
the appliance’s certification can be used.  Warranty will be voided if non-listed 
components are installed. 
Fan 
(134 to 212 CFM) 
Weight 
150 lb (68 kg) 
Electrical Connection 
AC 120V, 60 Hz 
Certification 
CSA certified according to ANSI Z21.88, CSA 2.33 
AFUE 
79% NG;   81% LP (up to 83% with extended vent of 7.2 ft [2.2 m] and no 
elbows) 
Venting 
Twin flue: maximum 6.5 ft with 2 elbows 
Concentric: maximum 33 ft with 3 elbows 
Specifications 
Rinnai is continually updating and improving products.  Therefore, specifications are subject to change without 
prior notice. 
 
Natural Gas 
Propane Gas 
Minimum supply gas pressure 
4.3 in (109 mm) W.C. 
9.8 in (249 mm) W.C. 
Maximum supply gas pressure 
10.5 in (267 mm) W.C. 
13.0 in (330 mm) W.C. 
Manifold test pressure 
Factory Set 
Factory Set 
BTU/hour input 
Natural Gas:  Low - 11,000 BTU/h;  High -  29,000 BTU/h 
Propane:  
Low - 11,000 BTU/h;  High -  28,000 BTU/h 
BTU/hour output 
Natural Gas:  Low - 8,635 BTU/h;  High -  21,900  BTU/h 
Propane:  
Low - 8,855 BTU/h;  High -  21,840 BTU/h