Troubleshooting 
Page 6-26
Operator Hears Tones 
6
Operator Hears Tones
6
Possible Cause: If the operator receives coverage calls intended for the VMS/AA 
because there were no ports available, the operator will hear the signalling 
information intended for the VMS/AA.
What to Do: Repair out of service ports or add more VMS ports as necessary so 
that overflow does not go to operator.
Calls From a Remote System Do Not
Reach the Centralized Voice 
Messaging System
6
The following are likely circumstances in which calls do not reach the centralized 
voice messaging system: 
System programming is incorrect. Some of the problems described in this 
section can occur when a system manager makes a change in a networked 
system’s local dial plan, non-local dial plan, switch identifier, or DS1 Switch 
Type setting. Ensure that your private network system forms are kept up to 
date and that changes are cleared with the coordinating system manager. 
Refer to possible causes and action to take below.
A selected tandem facility between the caller or called VMI extension is out 
of service. Check the error logs and if the error indicates an out of service 
condition, call the Lucent Technologies Helpline at 1 800 628-2888; 
consultation charges may apply.
No Touch-Tone Receivers (TTRs) available at a remote system when using 
tie trunks. This can be verified by checking for the 0c03 error on the error 
log on the remote switches. If this error persists, contact your local service 
representative.
A technician may be performing maintenance on tandem trunks included in 
the routes for the call.
A power failure may have occurred at the destination system or at another 
networked system whose tandem trunks are included in routes for the call. 
Possible Cause 1: Calling group used to route calls to the centralized VMS/AA is 
not programmed correctly or the coverage programming is not correct.
What to Do: Check the programming for the calling group:
Verity that the calling group type is Integrated VMI.
Verify that the calling group has a non-local member (VMI conversion 
number) assigned.
Check the coverage programming: