사용자 설명서차례1.1 AUDIENCE191.2 MANUAL ORGANIZATION191.3 TERMINOLOGY AND CONVENTIONS201.4 REFERENCES212.1 PRODUCT OVERVIEW232.2 KEY FEATURES232.3 Regulatory Compliance Standards252.4 HARDWARE REQUIREMENTS263.1 SAFETY, HANDLING, & ELECTROSTATIC DISCHARGE PROTECTION273.1.1 Safety Precautions273.1.2 Handling273.1.3 Electrostatic Discharge (ESD) Protection283.2 SPACE REQUIREMENTS29Figure 3-1 Dimensions for the Maxtor Atlas 10K III Hard Disk Drives293.2.1 Shock Feet303.3 UNPACKING INSTRUCTIONS30Figure 3-2 Drive Packing Assembly313.4 HARDWARE OPTIONS323.4.1 Configuration Jumpers and Connections323.4.2 Jumper Options on the 68-Pin Wide PCB32Figure 3-3 Jumper Locations on the 68-Pin Wide SCSI Drive PCB33Table 3-1 SCSI ID Selection on Option Connector (68-Pin SCSI Connector Drives)34Figure 3-4 Termination Power Circuitry363.4.3 SCA-2 80-Pin Connector Versions36Figure 3-5 Pin Locations on SCA-2 Connector37Table 3-2 SCSI ID Pin Assignments (SCA-2 Connector Versions of the Disk Drive)38Table 3-3 Spin Up on Power On Options393.4.4 Jumper J7 on the 80-Pin SCA PCB40Figure 3-6 J7 Jumper Location on the 80-Pin SCA PCB403.5 INTERFACE CONNECTOR (J1)41Figure 3-7 J1 Interface Connector Configurations413.5.1 68-pin Wide SCSI Connector - LVD42Table 3-4 68-Pin Wide LVD Pin Assignments423.5.2 80-pin SCA-2 SCSI Connector - LVD43Table 3-5 80-Pin SCA-2 LVD Pin Assignments433.5.3 68-Pin Wide Single-Ended SCSI Connector45Table 3-6 68-Pin Wide Single-Ended Pin Assignments453.5.4 80-pin SCA-2 Single-Ended SCSI Connector46Table 3-7 80-Pin SCA-2 Single-Ended Pin Assignments463.6 4-pin DC Power Connector (68-Pin Connector)47Table 3-8 Power Connector (J1, Section A)473.7 4-pin Mating Connector473.8 J1 12-pin Auxiliary Connector (68-pin Connector)48Table 3-9 J1 Auxiliary 12-Pin Connector483.9 DRIVE MOUNTING and installation493.9.1 Orientation49Figure 3-8 Mounting Dimensions Maxtor Atlas 10K III Drives493.9.2 Mounting Screw Clearance50Figure 3-9 Mounting Screw Clearance for Maxtor Atlas 10K III Drive503.9.3 Shock Clip513.9.4 Mounting513.9.5 Ventilation51Figure 3-10 Lengthwise Airflow Cooling51Figure 3-11 Crosswise Airflow Cooling524.1 SPECIFICATION SUMMARY53Table 4-1 Specifications534.2 FORMATTED CAPACITY55Table 4-2 Formatted Capacity554.3 DATA TRANSFER RATES564.4 TIMING SPECIFICATIONS56Table 4-3 Timing Specifications for Maxtor Atlas 10K III564.5 POWER574.5.1 Power Sequencing574.5.2 Power Reset Limits57Table 4-4 Power Reset Limits1574.5.3 Drive Power Dissipation58Table 4-5 Power Dissipation in Various Modes (Low-Profile Drives)584.6 ACOUSTICS59Table 4-6 Acoustical Characteristics—Sound Power per ISO 7779594.6.1 Acoustic Tonal Quality594.7 MECHANICAL604.8 ENVIRONMENTAL CONDITIONS60Table 4-7 Environmental Specifications604.9 ELECTROMAGNETIC CONDITIONS614.9.1 EMI/RFI Susceptibility614.9.2 Sensitivity to Magnetic Fields614.10 SHOCK AND VIBRATION62Table 4-8 Shock and Vibration Specifications624.11 RELIABILITY624.12 DISK ERRORS63Table 4-9 Error Rates635.1 Overview of the SCSI Command Descriptions65Table 5-1 Supported SCSI Commands655.2 Command Descriptor Block67Table 5-2 Typical (6-Byte) Command Descriptor Block-Data Format67Table 5-3 Command Descriptor Block-Field Descriptions67Table 5-4 Typical (6-Byte) Command Descriptor Block — Data Format68Table 5-5 Command Descriptor Block Control Field-Field Descriptions695.3 Status/Error Reporting70Table 5-6 Status Codes705.4 Auto Contingent Allegiance Condition and Contingent Allegiance Condition715.5 Extended Contingent Allegiance Condition725.6 Linked Commands735.7 DATA Transfer Command Components74Table 5-7 Length Fields74Table 5-8 DATA-Phase Command Contents745.8 SCSI COMMAND DESCRIPTIONS765.9 CHANGE DEFINITION Command (40h)77Table 5-9 CHANGE DEFINITION Command Descriptor Block-Data Format77Table 5-10 CHANGE DEFINITION-Field Descriptions775.10 FORMAT UNIT Command (04h)78Table 5-11 FORMAT UNIT Command Descriptor Block-Data Format79Table 5-12 FORMAT UNIT Command-Field Descriptions795.10.1 Five Forms of FORMAT UNIT Command s80Table 5-13 FORMAT UNIT Command Supported Options805.10.2 FORMAT UNIT Parameter List80Table 5-14 FORMAT UNIT Parameter List-Data Format80Table 5-15 .FORMAT UNIT Defect List Header-Data Format81Table 5-16 FORMAT UNIT Defect List Header-Field Descriptions81Table 5-17 FORMAT UNIT Defect Descriptor-Block Format82Table 5-18 FORMAT UNIT Defect Descriptor- Physical Sector and Bytes From Index Format82Table 5-19 FORMAT UNIT Initialization Pattern Descriptor-Data Format83Table 5-20 FORMAT UNIT Initialization Pattern Descriptor-Field Descriptions83Table 5-21 FORMAT UNIT Initialization Pattern Type835.11 INQUIRY Command (12h)84Table 5-22 INQUIRY Command Descriptor Block-Data Format84Table 5-23 INQUIRY Command Descriptor Block-Field Descriptions845.11.1 Standard Inquiry Data Page85Table 5-24 Standard Inquiry Data Page-Data Format85Table 5-25 Standard Inquir Data Page-Field Descriptions855.11.2 Vital Product Data Pages87Table 5-26 Supported Vital Product Data Pages -Data Format87Table 5-27 Vital Product Data-Page Codes87Table 5-28 Unit Serial Number Page-Data Format88Table 5-29 Unit Serial Number Page-Field Descriptions88Table 5-30 Implemented Operating Definition Page-Data Format89Table 5-31 Implemented Operating Definition Page-Field Descriptions89Table 5-32 ASCII Implemented Operating Definition Page - Data Format90Table 5-33 Device Identification Page - Data Format91Table 5-34 Device Identification Page-Field Description91Table 5-35 Firmware Revision Page -Data Format93Table 5-36 Maxtor Manufacturing Information Page-Data Format94Table 5-37 Negotiated Rate Information Page-Data Format95Table 5-38 Negotiated Rate Information Page-Field Descriptions96Table 5-39 Command Support Data Page-Data Format97Table 5-40 Command Support Data Page-Field Descriptions97Table 5-41 Command Support Data Page Command or Operation Codes985.12 LOG SELECT Command (4Ch)100Table 5-42 LOG SELECT Command Descriptor Block-Data Format100Table 5-43 LOG SELECT Command Descriptor Block-Field Descriptions1005.13 LOG SENSE Command (4Dh)101Table 5-44 Disk Drive Log Pages1015.13.1 LOG SENSE Command Descriptor Block102Table 5-45 LOG SENSE Command Descriptor Block-Data Format102Table 5-46 LOG SENSE Command Descriptor Block-Field Descriptions1025.13.2 LOG SENSE Log Pages103Table 5-47 LOG SENSE Log Page Format-Data Format103Table 5-48 LOG SENSE Log Page Format-Field Descriptions103Table 5-49 Generic Log Parameter-Data Format103Table 5-50 Generic Log Parameter-Field Descriptions1045.14 MODE SELECT (6) Command (15h)105Table 5-51 MODE SELECT (6) Command Descriptor Block-Data Format105Table 5-52 MODE SELECT (6) Command Field Descriptions1055.14.1 Initiator-Changeable Mode Pages106Table 5-53 Initiator-Changeable Mode Pages1065.14.2 Mode Page Types107Table 5-54 Mode Page Types1075.14.3 Mode Parameter List108Table 5-55 Mode Parameter List-Data Format108Table 5-56 Mode Parameter List-Field Descriptions108Table 5-57 Mode Parameter Header (6-Byte)-Data Format108Table 5-58 Mode Parameter Header- Field Descriptions108Table 5-59 Mode Parameter Block Descriptor-Data Format109Table 5-60 Mode Parameter Block Descriptor-Field Descriptions109Table 5-61 Categories of Changeable Pages110Table 5-62 Unit Attention Condition Page (Page 0)111Table 5-63 Unit Attention Condition Page (Page 0)111Table 5-64 Read-Write Error Recovery Page-(Page 1)112Table 5-65 Read-Write Error Recovery Page-(Page 1)112Table 5-66 Disconnect–Reconnect Page (Page 2)114Table 5-67 Disconnect-Reconnect-Field Descriptions (Page 2)114Table 5-68 Verify Error Recovery Page-(Page 7)116Table 5-69 Verify Error Recovery Page-Field Descriptions (Page 7)116Table 5-70 Caching Page-(Page 8)117Table 5-71 Caching Page-(Page 8)118Table 5-72 Control Mode Page-(Page 0Ah)120Table 5-73 Control Mode Page-Field Descriptions (Page 0Ah)121Table 5-74 Notch and Partition Page-(Page 0Ch)122Table 5-75 Notch and Partition Page-Field Descriptions (Page 0Ch)123Table 5-76 Port Control Page Short Format124Table 5-77 Port Control Page Long Format125Table 5-78 Power Condition Page-(Page 1Ah)126Table 5-79 Power Condition Page-Field Descriptions (Page 1Ah)127Table 5-80 Information Exceptions Control Page-(Page 1Ch)128Table 5-81 Information Exceptions Control Page-Field Descriptions (Page 1Ch)129Table 5-82 Codes Used by the MRIE Field130Table 5-83 Maxtor-Unique Page-Data Format (Page 39h)131Table 5-84 Maxtor-Unique Page-Field Descriptions (Page 39h)1325.15 MODE SELECT (10) Command (55h)137Table 5-85 MODE SELECT (10) Command Descriptor Block-Data Format137Table 5-86 Mode Parameter Header (10-Byte)-Data Format137Table 5-87 Mode Parameter Block Descriptor-Data Format137Table 5-88 Mode Parameter Block Descriptor-Field Descriptions1385.16 MODE SENSE (6) Command (1Ah)139Table 5-89 MODE SENSE (6) Command Descriptor Block-Data Format139Table 5-90 MODE SENSE Command-Field Descriptions139Table 5-91 Mode Parameter Header (6 Byte)-Data Format139Table 5-92 Mode Parameter Header-Field Descriptions1405.16.1 Read-Only Mode Pages141Table 5-93 Read-Only Mode Pages1415.16.2 Format Device Page (03h)142Table 5-94 Format Device Page-(Page 3)142Table 5-95 Format Device Page-Field Descriptions (Page 3)1435.16.3 Rigid Disk Geometry Page (04h)144Table 5-96 Rigid Disk Geometry Page-(Page 4)144Table 5-97 Rigid Disk Geometry Page-Field Descriptions (Page 4)1445.16.4 Margin Control Subpage146Table 5-98 Margin Control Subpage (01h)1465.16.5 Saved Training Configuration Values Subpage147Table 5-99 Saved Training Configuration Subpage (02h)1475.16.6 Negotiated Settings Subpage148Table 5-100 Negotiated Settings Subpage (03h)148Table 5-101 Bus Mode1485.16.7 Maxtor-Unique Caching Page (38h)149Table 5-102 Maxtor-Unique Caching Page-(Page 38h)149Table 5-103 Maxtor-Unique Caching-Field Description (Page 38h)1495.17 MODE SENSE (10) Command (5Ah)150Table 5-104 MODE SENSE (10) Command Descriptor Block-Data Format150Table 5-105 Mode Parameter Header (10 Byte)-Data Format150Table 5-106 Mode Parameter Block Descriptor-Data Format150Table 5-107 Mode Parameter Header & Block Descriptor -Field Descriptions1515.18 PERSISTENT RESERVATION IN Command (5Eh)152Table 5-108 PERSISTENT RESERVATION IN Command Descriptor Block-Data Format152Table 5-109 PERSISTENT RESERVATION IN Command-Field Descriptions153Table 5-110 Read Keys Parameters-Data Format153Table 5-111 Read Keys Parameters-Field Descriptions154Table 5-112 Read Reservations Parameters-Data Format154Table 5-113 Read Reservations Parameters-Field Descriptions155Table 5-114 PERSISTENT RESERVATION IN Read Reservations Descriptor-Data Format155Table 5-115 PERSISTENT RESERVATION IN Read Reservations Descriptor-Field Descriptions156Table 5-116 Persistent Reservation Type Codes and Their Meanings157Table 5-117 When Do Conflicts Between Existing Reservations and New Reservations Exist?1585.19 PERSISTENT RESERVATION OUT Command (5Fh)160Table 5-118 PERSISTENT RESERVATION OUT Command Descriptor Block-Data Format160Table 5-119 PERSISTENT RESERVATION OUT Command-Field Descriptions161Table 5-120 PERSISTENT RESERVATION OUT Command’s Service Action Descriptions162Table 5-121 Persistent Reservation Type Codes and Their Meanings166Table 5-122 .PERSISTENT RESERVATION OUT Parameter List-Data Format167Table 5-123 PERSISTENT RESERVATION OUT Parameter List-Field Descriptions168Table 5-124 Device Server Interpretation of Service and Scope Value1695.20 READ (6) Command (08h)170Table 5-125 READ (6) Command-Data Format170Table 5-126 READ (6) Command -Field Descriptions1705.21 READ (10) Command (28h)171Table 5-127 READ (10) Command -Data Format171Table 5-128 READ (10) Command -Field Descriptions1715.22 READ BUFFER Command (3Ch)172Table 5-129 READ BUFFER Command-Data Format172Table 5-130 READ BUFFER Command -Field Descriptions1735.23 READ CAPACITY Command (25h)174Table 5-131 READ CAPACITY Command-Data Format174Table 5-132 READ CAPACITY Command -Field Descriptions174Table 5-133 READ CAPACITY Returned Data-Data Format1745.24 READ DEFECT DATA Command (10) (37h)175Table 5-134 READ DEFECT DATA (10) Command -Data Format175Table 5-135 READ DEFECT DATA (10) Command -Field DescriptionREAD DEFECT176Table 5-136 Defect Descriptor-Block Format.176Table 5-137 Defect Descriptor-Bytes From Index Format, or Physical Sector Format176Table 5-138 Defect List Header -Data Format177Table 5-139 Defect List Header -Field Descriptions1775.25 READ DEFECT DATA Command (12) (B7h)178Table 5-140 READ DEFECT DATA (12) Command -Data Format178Table 5-141 READ DEFECT DATA (12) Command-Field Description179Table 5-142 Defect Descriptor-Block Format179Table 5-143 Defect Descriptor-Bytes From Index Format, or Physical Sector Format179Table 5-144 Defect List Header-Data Format180Table 5-145 Defect List Header -Field Descriptions1805.26 READ LONG Command (3Eh)181Table 5-146 READ LONG Command Descriptor Block-Data Format181Table 5-147 READ LONG Command Descriptor Block-Field Descriptions181Table 5-148 READ LONG Command -Returned Data1815.27 READ SKIP MASK Command (E8h)183Table 5-149 READ SKIP MASK Command -Data Format183Table 5-150 READ SKIP MASK Command -Field Descriptions1835.28 REASSIGN BLOCKS Command (07h)184Table 5-151 REASSIGN BLOCKS Command Descriptor Block-Data Format184Table 5-152 REASSIGN BLOCKS Defect List Header-Data Format184Table 5-153 REASSIGN BLOCKS Defect List Header -Field Description184Table 5-154 REASSIGN BLOCKS Defect Descriptor-Data Format1855.29 RECEIVE DIAGNOSTIC RESULTS Command (1Ch)186Table 5-155 Diagnostic Pages Supported by The Drives186Table 5-156 RECEIVE DIAGNOSTIC RESULTS Command Descriptor Block-Data Format186Table 5-157 RECEIVE DIAGNOSTIC RESULTS Command Descriptor Block-Field Descriptions1865.29.1 Supported Diagnos187Table 5-158 Supported Diagnostics Pages Page-Data Format1875.29.2 Translate Address Page (40h)188Table 5-159 Translate Address Page-Data Format188Table 5-160 Translate Address Page-Field Descriptions1895.30 RELEASE (6) Command (17h)190Table 5-161 RELEASE (6) Command Descriptor Block-Data Format190Table 5-162 RELEASE (6) Command -Field Descriptions1905.31 RELEASE (10) Command (57h)191Table 5-163 RELEASE (10) Command Descriptor Block-Data Format191Table 5-164 RELEASE (10) Command — Field Descriptions1925.32 REPORT DEVICE IDENTIFIER Command (A3h)193Table 5-165 REPORT DEVICE IDENTIFIER Command Descriptor Block-Data Format193Table 5-166 REPORT DEVICE IDENTIFIER Command Descriptor Block-Field Descriptions194Table 5-167 .REPORT DEVICE IDENTIFIER Parameter List-Data Format194Table 5-168 REPORT DEVICE IDENTIFIER Parameter List-Field Descriptions1945.33 REPORT LUNS Command (A0h)195Table 5-169 REPORT LUNS Command Descriptor Block-Data Format195Table 5-170 REPORT LUNS Command Descriptor Block-Field Description195Table 5-171 LUN Reporting Parameter List -Data Format1955.34 REQUEST SENSE Command (03h)196Table 5-172 REQUEST SENSE Command Descriptor Block-Data Format196Table 5-173 REQUEST SENSE Command Descriptor Block-Field Description1965.34.1 Sense Data Availability1975.34.2 Status Reporting1985.34.3 Sense Data Format for Error Code 70h and Error Code 71h199Table 5-174 Sense Data Format for Error Code 70h or 71h-Data Format199Table 5-175 Sense Data Fields (Error Code 70h)-Field Descriptions199Table 5-176 Supported Sense Key s201Table 5-177 Sense Key Information Field Contents202Table 5-178 Supported Additional Sense Codes and Sense Code Qualifiers (in Hex)203Table 5-179 Sense-Key Specific Field Contents216Table 5-180 ILLEGAL REQUEST Sense Key Field Pointer Bytes\Data Format216Table 5-181 ILLEGAL REQUEST Sense Key Field Pointer Bytes \Field Descriptions217Table 5-182 NOT READY Sense Key - Progress Indication Bytes\Data Format217Table 5-183 NOT READY Sense Key - Progress Indication Bytes\Field Descriptions217Table 5-184 MEDIUM ERROR or RECOVERED ERROR Sense Key - Retry Count-Data Format217Table 5-185 Table 5–90 MEDIUM ERROR or RECOVERED ERROR Sense Key - Retry Count2185.35 RESERVE (6) Command (16h)219Table 5-186 RESERVE (6) Command Descriptor Block-Data Format219Table 5-187 RESERVE (6) Command -Field Descriptions2195.36 RESERVE (10) Command (56h)220Table 5-188 RESERVE (10) Command Descriptor Block-Data Format220Table 5-189 RESERVE (10) Command -Field Descriptions220Table 5-190 Extent Descriptors-Data Format221Table 5-191 Reservation Types221Table 5-192 Parameter List When LongID and Extent Bits = 1-Data Format221Table 5-193 RESERVE (10) ID Only Parameter List-Data Format2215.37 REZERO UNIT Command (01h)222Table 5-194 REZERO UNIT Command Descriptor Block-Data Format2225.38 SEEK (6) Command (0Bh)223Table 5-195 SEEK (6) Command Descriptor Block-Data Format2235.39 SEEK (10) Command (2Bh)224Table 5-196 SEEK (10) Command Descriptor Block-Data Format2245.40 SEND DIAGNOSTIC Command (1Dh)225Table 5-197 SEND DIAGNOSTIC Command Descriptor Block-Data Format225Table 5-198 SEND DIAGNOSTIC Command -Field Descriptions2255.40.1 Supported Diagnostic Page List227Table 5-199 Supported Diagnostic Page List -Data Format2275.40.2 Translate Address Page228Table 5-200 Translate Address Page-Data Format2285.41 SET DEVICE IDENTIFIER Command (A4h)229Table 5-201 SET DEVICE IDENTIFIER Command Descriptor Block-Data Format229Table 5-202 SET DEVICE IDENTIFIER Command Descriptor Block-Field Descriptions229Table 5-203 SET DEVICE IDENTIFIER Parameter List-Data Format229Table 5-204 SET DEVICE IDENTIFIER Parameter List-Field Descriptions2295.42 START STOP UNIT Command (1Bh)230Table 5-205 START STOP UNIT Command Descriptor Block-Data Format230Table 5-206 START STOP UNIT Command-Field Descriptions2305.43 SYNCHRONIZE CACHE Command (35h)231Table 5-207 SYNCHRONIZE CACHE Command Descriptor Block-Data Format231Table 5-208 SYNCHRONIZE CACHE Command -Field Descriptions2315.44 TEST UNIT READY Command (00h)232Table 5-209 TEST UNIT READY Command Descriptor Block-Data Format2325.45 VERIFY Command (2Fh)233Table 5-210 VERIFY Command Descriptor Block-Data Format233Table 5-211 VERIFY Command-Field Descriptions2335.46 WRITE (6) Command (0Ah)234Table 5-212 WRITE (6) Command Descriptor Block-Data Format234Table 5-213 WRITE (6) Command -Field Descriptions2345.47 WRITE (10) Command (2Ah)235Table 5-214 WRITE (10) Command Descriptor Block-Data Format235Table 5-215 WRITE (10) Command -Field Descriptions2355.48 WRITE AND VERIFY Command (2Eh)236Table 5-216 WRITE AND VERIFY Command Descriptor Block-Data Format236Table 5-217 WRITE AND VERIFY Command -Field Descriptions2365.49 WRITE BUFFER Command (3Bh)237Table 5-218 WRITE BUFFER Command Descriptor Block-Data Format237Table 5-219 WRITE BUFFER Command -Field Descriptions2385.50 WRITE LONG Command (3Fh)239Table 5-220 WRITE LONG Command Descriptor Block-Data Format239Table 5-221 WRITE LONG Command-Field Descriptions2395.51 WRITE SAME Command (41h)240Table 5-222 WRITE SAME Command Descriptor Block-Data Format240Table 5-223 WRITE SAME Command-Field Descriptions2405.52 WRITE SKIP MASK Command (EAh)241Table 5-224 WRITE SKIP MASK Command Descriptor Block -Data Format241Table 5-225 WRITE SKIP MASK Command -Field Descriptions2416.1 KEY FEATURES2436.2 PREFETCH2446.3 WRITE-BACK CACHING2456.4 ZERO LATENCY READ/WRITE2456.5 DISCONNECT-RECONNECT2456.6 TRACK AND CYLINDER SKEWING2456.7 AVERAGE ACCESS TIME2466.8 EMBEDDED SERVO SYSTEM2466.9 DATA INTEGRITY AND SECURITY2466.9.1 Media Error Protection2466.9.2 Transfer Error Protection2466.9.3 Addressing Error Protection2466.9.4 Data Sector Reallocation Error Protection2476.9.5 Data Verification2476.10 TAGGED COMMAND QUEUING2476.11 COMMAND REORDERING2476.12 BANDED RECORDING2486.13 SPECIAL FUNCTIONS2486.14 POWER MANAGEMENT2486.15 DIAGNOSTICS2486.15.1 Power On Self Test (POST)2496.15.2 Periodic Self-Adjustments2496.15.3 Host Diagnostics2496.15.4 Log Sense2506.16 ERROR RECOVERY2506.16.1 Seek Error Recovery2506.16.2 Data Read Errors2506.16.3 Reallocation of Bad Blocks2506.17 SCSI CONFIGURED AUTOMATICALLY (SCAM)2516.18 THE ULTRA160 and ULTRA320 LOW VOLTAGE DIFFERENTIAL (LVD) SCSI INTERFACE2516.18.1 DIFFSENS2526.18.2 DIFFSENS SWITCHING2526.18.3 DT AND ST CLOCKING253Figure 6-1 ST and DT CLocking2536.18.4 CYCLIC REDUNDANCY CHECKING2546.18.5 DOMAIN VALIDATION2546.18.6 Adaptive Active Filter (AAF)2546.18.7 Transmitter Pre-Compensation with Cutback2556.18.8 Free Running Clock (FRC)2556.18.9 Skew Compensation2556.18.10 Information Unit Transfers2556.19 HOT PLUGGING/REMOVAL AND INSERTION OF SCSI DEVICES2556.19.1 System Considerations2566.19.2 APPLICABLE SCSI PHYSICAL DOCUMENTS257A.1 SCSI-2/SCSI-3 Equivalent Terminology259Table A-1 SCSI-2/SCSI-3 Equivalent Terminology259A.2 SCSI Commands and Messages260Table A-2 SCSI-3 Quick Reference – Commands260Table A-3 SCSI-3 Quick Reference – Messages261A.3 SCSI Pages261Table A-4 SCSI-3 Quick Reference - Pages261A.4 Sense Keys263Table A-5 SCSI-3 Quick Reference – Sense Keys263A.5 Status Codes263Table A-6 SCSI-3 Quick Reference – Status Codes263B.1 TRANSFER PERIOD FACTOR FIELD265Table B-1 Transfer Period Factor Field Values When PARL = 1265Table B-2 Transfer Period Factor Field Values When PARL = 0266B.2 Settings for the QAS, DT, and IU fields266Table B-3 Settings for the QAS, DT, and IU Fields of the Negotiated Rate Information Page (INQUIR...266크기: 6.57메가바이트페이지: 284Languages: English, Français매뉴얼 열기