Graco 312374J Manual Do Utilizador

Página de 16
Integrated Air Controls
312374J
3
Integrated Air Controls
Pressure Relief Procedure
1.
Close the air motor slider valve (E) and the main air 
slider valve (F).
2.
Set the ram director valve to DOWN. The ram will 
slowly drop.
3.
Jog the director valve up and down to bleed air from 
ram cylinders. 
Disassembly
1.
For Supply Systems with Shrouds: Remove 
shrouds. Loosen six captive screws (A) and disas-
semble shrouds (B) from supply system.
2.
Disconnect all hoses and tubing from existing air 
control.
3.
Remove four screws (C) from the mounting bracket 
(D) and remove the integrated air controls from the 
supply system.
To reduce the risk of serious injury whenever you are 
instructed to relieve the pressure, follow the 
Pressure 
Relief Procedure.
F
IG
. 1
A
B
B
r_289105_312375_a
255650 (shown)
F
IG
. 2
F
IG
. 3
If you are not replacing the manifold (1), you may 
prefer to remove the bracket from the ram and 
leave it attached to the integrated air controls 
because the screws are easier to reach. See F
C
1
E
F
r_289105_312375_2a
D
255650 (shown)
r_289105_312375_3a
C
D
E
F
1