Datalogic Scanning D8330 Manual Do Utilizador

Página de 212
POWERSCAN
®
 D8330/M8300 
156 
 
 
5.5.2 
Enter Sleep Timeout 
 
For readers that have the Sleep state enabled, this timeout determines when the 
reader will enter this state. 
 
 
5.6  READING PARAMETERS 
 
5.6.1 
Trigger Signal 
 
This mode determines how the reading phase is controlled when the hardware 
trigger operating mode is selected: 
•  trigger active level: the reader goes ON when the trigger is pressed and goes 
OFF when it is released 
•  trigger active pulse: the reader goes ON at the first trigger press and goes OFF 
only at a second press 
 
 
5.6.2 
Trigger Click 
 
When enabled, it activates a "click" sound upon each trigger pressure. 
 
 
5.6.3 
Trigger-Off Timeout 
 
When this timeout is selected, the reader turns OFF automatically after the desired 
period of time. 
 
 
5.6.4 
Reads per Cycle 
 
In general, a reading cycle corresponds to the ON + OFF times of a device. 
The resulting effects of this parameter on code reading depend on other related 
configuration conditions. Here are the definitions of ON and OFF times. 
 
•  For readers using the software trigger parameter (FLASH MODE), a reading 
cycle corresponds to the flash on + flash off times. Code reading takes place 
during the flash on time. 
•  For readers using the hardware trigger parameter, a reading cycle corresponds 
to a trigger press (ON) + one of the following OFF events: 
trigger release (for trigger active level
a second trigger press (for trigger active pulse
trigger-off timeout (see par. 5.6.3).