Installation
17
800937
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Step 10: Plug In the Washer and Dryer
Refer to sections on Electrical Requirements and 
connect the washer and dryer to an electrical power 
source.
Figure 19 
Figure 20 
Figure 21 
Step 11: Check Installation
Refer to Installer Checklist on the back cover and 
make sure that unit is installed correctly.
Moving Unit to a New Location 
To prevent damage while moving the unit, the 
shipping materials MUST BE reinstalled.
Reinstallation of Shipping Materials
Remove front access panel by removing two screws.
Place the shock sleeves on all four shock absorbers. 
Refer to Figure 22.
Insert hooked end of shipping brace into the open slot 
of the motor mount. Attach with bolts and lockwashers. 
Refer to Figure 22.
Reinstall front access panel.
Figure 22 
Refer to step 8 for proper procedures whenever the 
unit is moved.
D254I
D275I
D254I
D254I
WASHER
Plug cord into separately fused 15 Amp circuit.
ELECTRIC DRYER
Connect to 30 Amp circuit.
D254I
GAS DRYER
Plug cord into separately fused 15 Amp circuit.
H336I
1
Shock Sleeves
2
Motor Mount
3
Bolts and Lockwashers
4
Hooked End of Shipping Brace
2
1
4
3