GAS SUPPLY CONNECTION REQUIREMENTS 
Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting 
 
between the flexible gas connector and the dryer gas pipe,  
as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
 
®†
 tape.
This dryer must be connected to the gas supply line with a 
 
listed flexible gas connector that complies with the standard 
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
A. 1/2" NPT gas supply line
B. 3/8" NPT dryer pipe
NOTE: If the dryer is mounted on a pedestal, the gas pipe height 
must be an additional 10" (254 mm) or 15.5" (394 mm) from the 
floor, depending on the pedestal model. For a garage installation, 
the gas pipe height must be an additional 18" (460 mm) from  
the floor.
1
/
8
"
(54 mm)
1"
(25 mm)
A
B
 
1/2" IPS pipe is recommended.
 
3/8" approved aluminum or copper tubing is acceptable for 
 
lengths under 20 ft. (6.1 m) if local codes and gas supplier 
permit. 
If you are using Natural gas, do not use copper tubing.
 
Lengths over 20 ft. (6.1 m) should use larger tubing and  
 
a different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP 
 
compatible copper tubing can be used. If the total length of 
the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas 
must be used. Do not use TEFLON
®† 
tape.
Must include shut-off valve
 
In the U.S.A.:
An individual manual shut-off valve must be installed within  
six (6) ft. (1.8 m) of the dryer in accordance with the National 
Fuel Gas Code, ANSI Z223.1. The location should be easy to 
reach for opening and closing. 
In Canada:
An individual manual shut-off valve must be installed in 
accordance with the B149.1, Natural Gas and Propane  
Installation Code. It is recommended that an individual 
manual shutoff valve be installed within six (6) ft. (1.8 m) of 
the dryer. The location should be easy to reach for opening 
and closing. 
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter fitting 
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve.
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualified 
technician.
No attempt shall be made to convert the dryer from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting your gas company.
GAS SUPPLY LINE
Must include 1/8" NPT minimum plugged tapping accessible 
 
for test gauge connection, immediately upstream of the gas 
connection to the dryer. 
A
B
E
D
C
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
Prepare dryer for leveling legs
1. 
To avoid damaging floor, use a large flat piece of cardboard 
from dryer carton; place under entire back edge of dryer. 
Firmly grasp dryer body (not console panel) and gently lay 
dryer down on cardboard.
INSTALL LEvELING LEGS
BURNER INPUT REQUIREMENTS
Elevations above 10,000 ft. (3,048 m):
When installed above 10,000 ft. (3,048 m) a 4% reduction 
 
of the burner Btu rating shown on the model/serial number 
plate is required for each 1,000 ft. (305 m) increase in 
elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping 
 
system during pressure testing at pressures greater than  
1/2 psi.
DRYER GAS PIPE
The gas pipe that comes out through the rear of your dryer 
 
has a 3/8" male pipe thread.