Determine vent length and elbows needed for best 
drying performance
Use the following Vent system chart to determine type of vent 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the 
Vent system chart. Exhaust systems longer than those specified 
will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and 
increased energy usage.
The Vent system chart provides venting requirements that will help 
to achieve the best drying performance.
Vent system chart
NOTE: Performance of rear exhaust to either side of the dryer is 
equivalent to adding one elbow. To determine maximum exhaust 
length, add one elbow to the chart.   
Number of 
90º turns 
or elbows
Type of
vent
Box or 
Louvered 
hoods
Angled
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
Rigid metal
54 ft (16.5 m) 
48 ft (14.6 m)
2
Rigid metal
44 ft (13.4 m)
38 ft (11.6 m)
3
Rigid metal
35 ft (10.7 m)
29 ft (8.8 m)
4
Rigid metal
27 ft (8.2 m)
21 ft (6.4 m)
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior wall 
opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. 
Secure vent to exhaust hood with 4" (102 mm) clamp.
3. Run vent to dryer location. Use the straightest path possible. See 
“Determine vent path” in “Plan Vent System.” Avoid 90º turns. 
Use clamps to seal all joints. Do not use duct tape, screws, or 
other fastening devices that extend into the interior of the vent to 
secure vent, because they can catch lint.
Install Leveling Legs
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To avoid damaging the floor, use a large, flat piece of cardboard 
from the dryer carton. Place cardboard under the entire back 
edge of the dryer. 
2. Firmly grasp the body of the dryer (not the top or console panel). 
Gently lay the dryer on the cardboard. See illustration.   
3. Examine the leveling legs. Find the diamond marking. 
4. Screw the legs into the leg holes by hand. Use a wrench to finish 
turning the legs until the diamond marking is no longer visible.
5. Place a carton corner post from dryer packaging under each of 
the 2 dryer back corners. Stand the dryer up. Slide the dryer on 
the corner posts until it is close to its final location. Leave enough 
room to connect the exhaust vent.
Connect Vent
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in 
dryer. If connecting to existing vent, make sure the vent is clean. 
The dryer vent must fit over the dryer exhaust outlet and inside the 
exhaust hood. Check that the vent is secured to exhaust hood 
with a 4" (102 mm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. Once the exhaust vent connection is made, remove the corner 
posts and cardboard.
Connect Inlet Hose
The dryer must be connected to the cold water faucet using the new 
inlet hoses. Do not use old hoses.
1. Turn cold water faucet off and remove washer inlet hose.
2. Remove old rubber washer from inlet hose and replace with new 
rubber washer provided. If space permits, attach the brass female 
end of the “Y” connector to the cold water faucet.
NOTE: If “Y” connector can be attached directly to cold water 
faucet, go to Step 6. If “Y” connector cannot be attached 
directly to the cold water faucet, the short hose must be used. 
Continue with Step 3.
3. Attach short hose to cold water faucet. Screw on coupling by 
hand until it is seated on faucet. 
4. Using pliers, tighten the couplings with an additional two-thirds 
turn. 
NOTE: Do not overtighten. Damage to the coupling can result.
5. Attach “Y” connector to brass male end of small hose. Screw on 
coupling by hand until it is seated on connector.
6. One end of the long hose has a wire mesh strainer inside the 
coupling. Attach this end to the “Y” connector.
7. Attach washer cold inlet hose to other end of “Y” connector.  
Screw on coupling by hand until it is seated on connector.