Whirlpool W10164159B Manual Do Utilizador

Página de 56
7
Electrical Requirements - Canada Only
WARNING
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in 
conformance with the Canadian Electrical Code, C22.1-latest 
edition and all local codes. A copy of the above codes standard 
may be obtained from: Canadian Standards Association, 178 
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt, 60 Hz., 
AC only electrical supply on a separate 30-amp circuit, fused on 
both sides of the line. A time-delay fuse or circuit breaker is 
recommended. Connect to an individual branch circuit.
This dryer is equipped with a CSA International Certified Power 
Cord intended to be plugged into a standard 14-30R wall 
receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall 
receptacle is within reach of dryer’s final location.
4-wire receptacle 14-30R
Do not use an extension cord.
If you are using a replacement power supply cord, it is 
recommended that you use Power Supply Cord Replacement Part 
Number 3394208. For further information, please reference the 
service numbers located in the “Assistance or Service” section
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment- 
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.
.