Fujitsu C150-E049-02EN Manual Do Utilizador

Página de 236
M3099GX/GH OEM Manual
C-2
5 Lift the document sensor
unit and keep it at the upper
position with one hand and
pull the roller ASY out with
the other hand.
6 Move the guide on the
hopper table completely to
the end.
7 Hold both ends of the guide
plate and press them down
to remove the guide.
8 Adjust the separation
pressure by using the separa-
tion pressure adjustment
lever according to paper feed
error as follows:
• Slip feed:
Turn clockwise by 45
°
. (In-
crease the separation pressure.)
• Double feed:
Turn counter-clockwise by 45
°
.
(Decrease the separation pres-
sure.)
Notice:
If the paper feed error reccur,
try this adjustment again until
the lever stops.
Hopper table
Guide
Guide plate
Separation pressure
adjustment lever
Slip feed
Double feed