Then select the specified command Off, On, or Set. 
 
 
UPB Link Triggers 
 
When a program is created that uses “When Link On” as the trigger, the program will execute when a “Link Activate”, “Link 
Goto” (as long as the result of the Goto command is not “0”), or “Link Fade Start” (as long as the result to the Fade command is 
not “0”) message is received.   
 
When a program is created that uses “When Link Off” as the trigger, the program will execute when a “Link Deactivate” or “Link 
Goto” (where the result of the Goto command is “0”) message is received. 
 
Using HAI PC Access Software, you can create a program that uses “When Link Fade Stop” as the trigger.  When this trigger is 
used, the program will execute when the “Link Fade Stop” message is received. 
 
 
Alarm Event Buttons 
 
 
 
Pressing the 5 (ALARM) key allows you to specify a event button activated upon the occurrence of an alarm.  You are first 
prompted to select the type of alarm: 
 
 
 
 
SELECT ALARM TYPE      
 
 
 
 
ANY TYPE               
 
 
The arrow keys are used to select from a list of alarm types: 
 
• 
ANY ALARM
 
• 
BURGLARY ALARM
 
• 
FIRE ALARM 
 
• 
GAS ALARM
 
• 
AUXILIARY ALARM
 
• 
FREEZE ALARM
 
• 
WATER ALARM
 
• 
DURESS ALARM
 
• 
TEMPERATURE ALARM
 
 
Press the ' # ' key when the desired alarm type is shown.   
 
 
X-10 Event Buttons 
 
Pressing the 6 (X-10) key allows you to specify an event button activation upon receipt of an X-10 command from a source 
external to OmniLT.  OmniLT can also respond to scene changes initiated at Compose keypads and dimmers.  When a scene 
change is initiated, OmniLT can activate an event button program.  You are first prompted to enter the X-10 house code: 
 
   X-10 
HOUSE 
CODE:
 
   1-16=A-P
 
 
You are then prompted to enter the X-10 unit code: 
 
 
 
 
X-10 UNIT CODE:
 
 
 
 
1-16               0=ALL
 
 
Finally, you are prompted to specify the command that activates the event button: 
 
 
 
 
WHEN X-10 A1:
 
   0=OFF 
1=ON 
2=SCENE
 
 
 
 
 
After specifying the X-10 House Code and X-10 Unit Code, select 0 for Off, 1 for On, or 2 for Scene.   
 