Hitachi N5009AF Manual Do Utilizador

Página de 108
— 17 —
English
These units should always be used
Filter .............. The filter removes moisture and dirt mixed in 
compressed air. Drain daily unless fitted with an 
automatic drain. Keep the filter clean by regular 
maintenance. 
Regulator ...... The regulator controls the operating pressure for 
safe operation of the Tool. Inspect the regulator 
before operation to be sure it operates properly.
Lubricator ..... The lubricator supplies an oil mist to the Tool. 
Inspect the lubricator before operation to be sure 
the supply of lubricant is adequate. Use Hitachi 
pneumatic tool lubricant.
3. Air Hose
  Air hoses should have a minimum of 150 psi (10.4 bar  10.6 kgf/
cm
2
) working pressure rating or 150 percent of the maximum 
pressure that could be produced in the air system. The supply 
hose should contain a fitting that will provide “quick disconnect‑
ing” from the male plug on the Tool.
4. Hose Coupling
  Install a male plug on the Tool which is free flowing and which 
will release air pressure from the Tool when disconnected from 
the supply source. This Tool uses a 3/8” NPT. male plug. The in‑
side diameter should be .275” (7mm) or larger. The fitting must 
be capable of discharging Tool air pressure when disconnected 
from the air supply.
5. Air Consumption
  The Tool requires 4.2 cfm of free air to operate at the rate of 60 
fasteners per minute @ 80 psi. Take the actual rate at which the 
Tool will be run to determine the amount of air required. For in‑
stance, if your fastener usage averages 30 fasteners per minute, 
you need 50% of the Tools cfm. 
6. Operating Pressure
  70 to 90 psi.  Select the operating pressure within this range 
for best fastener performance. DO NOT EXCEED THIS RECOM‑
MENDED OPERATING PRESSURE.