2.  Determine the type of duct you have. 
(For flex duct applications, refer to Figure 21 on page 8) 
I
F YOU HAVE METAL DUCT
a.  Apply supplied wet and stick mounting template to air duct in 
either a vertical or horizontal position as shown in Figure 2. 
b.  Drill 1/8” diameter mounting holes at positions indicated on 
template. 
c.  Cut out the marked openings on template using a hole saw 
or a pair of tin snips or jigsaw. (See Figure 2)  
d.  Remove paper template from duct. 
I
F YOU HAVE DUCT BOARD
a.  Mount the supplied metal mounting plate onto the duct with 
duct tape in either a vertical or horizontal position as shown 
in Figure 2. (See Figure 3) 
b.  Bend tabs outward as shown in figure 4. 
c.  Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See 
Figure 5) 
d.  Remove the cut piece of duct. (See Figure 6) 
e.  Bend both tabs down and through duct at first bend point. (See Figures 7 & 8) 
f.  Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. 
(See Figures 9 & 10 
g.  Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See 
Figure 11) 
Figure 2
 
Figure 3
Figure 4
Figure 5
Figure 6
 
Figure 7
 
Figure 8
Figure 9
 
Figure 10
Figure 11
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness.  Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.