Table of Contents
Introduction
1
Features & Benefits
1
1. Intended Application
2
2. Registrations
2
3. Specifications
2
4. Operation
2
4.1 Humidity/Fan Control Panel
WITHOUT Fresh Air Ventilation or Damper
3
4.1A Humidity/Fan Control Panel WITH Fresh
Air Ventilation and WITHOUT Damper
3
4.1B Humidity/Fan Control Panel WITH
Fresh Air Ventilation AND Damper
3
4.1C Ventilation Timer and Humidity Control
WITH Fresh Air AND Motorized Damper
3
4.1D DEH 2000 Digital Controller WITH
Fresh Air AND Damper
3
4.1E DEH 2000 Digital COntroller
WITHOUT Fresh Air
4.2 Humidity Control Adjustment
3
4.3 Fan/Filter Switch
3
4.4 Ventilation Timer
3
4.5 Setting the Time
4
4.6 Ventilation Schedule
4
4.7 Automatic or Manual Mode
4
4.8 Low Pressure Control
4
5. DEH 2000 Digital Control
4
5.1 Specifications
4
5.2 Operation
4
5.2A Display
4
5.2B Setting
5
5.2C On/Off Setting
5
5.2D Setting Clock Time
5
5.2E Setting Relative Humidity Setpoint
5
5.2F Fan Setting and Operation
6
5.2G Fan On Fan Off Fan Program
6
5.2H Damper Operation and Setting
6
5.2I Intermittent/Programmed Ventilation 6
5.2J Programming Notes
5.2J Programming Notes
7
5.2K Stop Start
7
6. Maintenance
7
6.1 Standard Air Filter
7
6.2 High Efficiency Air Filter
7
6.3 Fresh Air Return
7
7. Service
7
7.1 Technical description
7
7.2 Troubleshooting
8
7.3 Refrigerant Charging
9
7.4 Impeller Fan Replacement
9
7.5 Compressor/Capacitor Replacement
9
7.6 Replacing Compressor - Nonburn Out
9
7.7 Electric Ventilation Damper
9
7.8 Condensate Pump Kit
9
8. Warranty
10
9. Optional Parts List
11
1 Intended Application for Ultra-Aire 135H
For the ideal installation, draw air from the central part of the
home and return it to isolated areas of the home like the bed-
rooms, den, utility room, or family room. The ductwork of the
existing heating system can be used to supply air to the home.
home and return it to isolated areas of the home like the bed-
rooms, den, utility room, or family room. The ductwork of the
existing heating system can be used to supply air to the home.
2 Registrations
The Ultra-Aire 135H (P/N 4025080) conforms to
UL STD 1995. Certified to CAN/CSA STD C22.2 No. 236.
UL STD 1995. Certified to CAN/CSA STD C22.2 No. 236.
3 Specifications
Model:
UA-135H Air Purifying Dehumidifier
Electrical:
110-120 VAC, 12 Amps, 60 Hz, grounded
Capacity:
135 pints/day @ 80°F, 60% RH
Operating Temp.: 55°F min., 100°F max.
Air Flow:
Air Flow:
355 CFM without external ducting
335 CFM @ .20 IWG external static
315 CFM @ .40 IWG external static
335 CFM @ .20 IWG external static
315 CFM @ .40 IWG external static
Refrigerant Charge:
1 lb., 12 oz. R22
Duct Connections:
Round 10" inlet, 10" outlet
Filter Size:
Pleated cloth: 2" X 20" X 24"
High Efficiency: 4" X 20" X 24"
High Efficiency: 4" X 20" X 24"
Unit Size (w/o duct collars):
31"L x 21"W x 18.65"H
Shipping Size:
37”L x 25”W x 28.5”H
Unit Weight:
100 lb.
Shipping Weight:
138 lb.
4 Operation
The Ultra-Aire UA-135H Air Purifying Dehumidifier performs
three functions in one compact enclosure; High-Capacity
Dehumidification, Fresh Air Ventilation, and Filtration. The
UA-135H can be equipped with various accessories to
enhance its operation. A remote control panel must be
used with the UA-135H. Your unit has one of three remote
control panels. To determine how each control operates
the UA-135H it must first be determined which control is
being used and whether or not the 135H is ducted for fresh
air ventilation. Refer to Section 7 to identify which control
you have installed. Inspect ducting or contact your installer
to determine if your UA-135H is ducted for outside air.
three functions in one compact enclosure; High-Capacity
Dehumidification, Fresh Air Ventilation, and Filtration. The
UA-135H can be equipped with various accessories to
enhance its operation. A remote control panel must be
used with the UA-135H. Your unit has one of three remote
control panels. To determine how each control operates
the UA-135H it must first be determined which control is
being used and whether or not the 135H is ducted for fresh
air ventilation. Refer to Section 7 to identify which control
you have installed. Inspect ducting or contact your installer
to determine if your UA-135H is ducted for outside air.
Humidity/Fan Control Panel (P/N 4024155)
4.1
4.1
Humidity/Fan Control Panel WITHOUT Fresh Air
Ventilation or Damper
Ventilation or Damper
4.1A
Humidity/Fan Control Panel WITH Fresh Air
Ventilation and WITHOUT Damper
Ventilation and WITHOUT Damper
4.1B
Humidity/Fan Control Panel WITH Fresh Air
Ventilation AND Damper
Ventilation AND Damper
Ventilation Timer/Humidity Control Panel (P/N 4024125)
4.1C
4.1C
Ventilation Timer and Humidity Control WITH Fresh
Air AND Motorized Damper
Air AND Motorized Damper
DEH 2000 Digital Control (P/N 4024539)
4.2
4.2
DEH 2000 Digital Controller WITH Fresh Air
AND Damper
AND Damper
4.2A
DEH 2000 Digital Controller WITHOUT Fresh Air