Installation  (for qualified installers only)
© Travis Industries
4080123
100-01174_002
Gas Line Requirements
MASSACHUSETTS INSTALLATIONS  -  WARNING:
THIS  PRODUCT  MUST  BE  INSTALLED  BY  A  LICENSED  PLUMBER  OR  GAS  FITTER  WHEN  INSTALLED  WITHIN  THE
COMMONWEALTH OF MASSACHUSETTS.
OTHER MASSACHUSETTS CODE REQUIREMENTS:
 
Flexible connector must not be longer than 36 inches.
 
Shutoff valve must be a “T” handle gas cock.
 
Only  direct  vent  sealed  combustion  products  are  approved  for  bedrooms  or  bathrooms.
 
Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.
 
A carbon monoxide (CO) detector is required in the same room as the appliance.
 
The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and the
requirements listed below.
 
A manual shutoff valve is required within 3’ of the heater.  It should be placed upstream of the flex line (if
used) and may be installed behind the access door inside the heater. ).
 
The heater and gas control valve must be disconnected from the gas supply piping during any pressure
testing  of  that  system  at  test  pressures  in  excess  of  1/2  psig.    For  pressures  under  1/2  psig,  isolate  the
gas  supply  piping  by  closing  the  manual  shutoff  valve.
 
Leak test all gas line joints and the gas control valve prior to and after starting the heater.
 
This heater is designed either for natural gas or for propane (but not for both).  Check the sticker on the top
of the gas control valve to make sure the correct fuel is used (see illustration on page 4).
 
Installation  must  be  performed  by  a  qualified  installer,  service  agency  or  the  gas  supplier  (In  Massachusetts
a  licensed  plumber/gasfitter).
Gas Line Location
The gas inlet 
accepts a 1/2" MPT.
3-1/8"
Shutoff Valve (secured to 
the fireplace insert)
Fireplace Opening
Gas Inlet Pressure
Standard  Input  Pressure
Natural  Gas
7" W.C. (1.74 kPA)
Propane
13" W.C. (2.73 kPA)
 
If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is
adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.
 
The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should
supply  gas  at  the  suggested  input  pressure  listed  above.    Contact  the  local  gas  supplier  if  the  regulator  is  at
an improper pressure.