Avalon Stoves DVL Insert EF II Manual Do Utilizador

Página de 44
6
Features and Specifications
© Travis Industries
4080123
100-01174_002
Features
 
Works During Power Outages (millivolt system)
 
High  Efficiency
 
Optional  Thermostat  or  Remote  Control
 
Ember Fyre™ Burner for "Wood Fire" Look
 
Quiet  Blower  for  Effective  Heat  Distribution
 
Convenient  Operating  Controls
 
Variable-Rate  Heat  Output
 
Low  Maintenance
Installation  Options
 
Residential  or  Mobile  Home
 
Fireplace  Insert
 
Masonry  or  Factory  Built  (Metal)  Wood-
Burning  Fireplace
Heating  Specifications
Natural  Gas
Propane
Approximate  Heating  Capacity  (in  square  feet)*
600  to  2,000
600  to  2,000
Maximum  BTU  Input  Per  Hour
40,000
40,000
Minimum  BTU  Output  on  Low
20,300
19,700
Steady  State  Efficiency**  (with  blowers  on)
Up to 79.3 %
Up to 81.2 %
AFUE  (Annual  Fuel  Utilization  Efficiency)
Up to 71.7 %
Up to 73.4 %
*
Heating  capacity  will  vary  with  floor  plan,  insulation,  and  outside  temperature.
**
Efficiency  rating  is  a  product  of  thermal  efficiency  rating  determined  under  continuous
operation  independent  of  installed  system.
Dimensions
44-3/16"* 8x10 Arch/Rect. Panels 
48-3/16"* 10x13 Rect. Panels
* Includes trim 
NOTE: on older style panels the 3/8" standoffs 
are no longer required and may be bent back.
20"
See the section "Vent Requirements" 
for vent location.
14-1/2"*
1-1/4"*
33-3/8"* 8x10 
Arch/Rect. Panels
 
36-3/8"* 10x13 
Rect. Panels
31-1/2"
23-3/4"