14.1 Window Refi tting & Checking 
Fit the window to the fi rebox. Insert the bottom middle spring-
loaded bolt and tighten it.
Locate the bottom 2 spring-loaded bolts, turning through 90 
degrees to lock them in position.
Repeat with the top 3 spring-loaded bolts.
Pull the top of the window and release it to check that it opens 
slightly and returns in place in the event of a delayed 
ignition explosion. Similarly, check the bottom of the 
window by pulling it forward and releasing it.
14.2 Glass Replacement
In the event that the glass is damaged, the door and glass will 
be replaced only as a complete assembly, as supplied by the 
manufacturer.
Remove the broken glass pieces (be sure to wear gloves) then 
remove the window frame. See section 9.1 for window removal.
Contact the manufacturer for replacement window part #4000084S.
See section 14.1 above for window refi tting.
1.
2.
3.
4.
1.
2.
3.
Window Refi tting
15.1 Burner & Pilot Checks
Check ignition, pilot stability, burner fl ames and the full range of the thermostat settings using the rotary 
switch inside the appliance and all other controls (remote handset). See the lighting and remote control 
instructions further on in this manual for full details.
15.2 Aeration Adjustment
The burner aeration is adjustable.
For the vast majority of installations, no 
adjustment will be necessary. However, in a very 
few instances, performance may be improved by 
sliding the shutter to adjust the aeration.
Evaluate the aeration only after the unit has 
warmed-up—approximately 15 minutes.
Increasing aeration will cause the fl ames to 
appear more transparent and blue making the 
ceramic fuel effects glow more.
Decreasing aeration will cause the fl ames to appear more yellow or orange making the fuel effects glow 
less. 
Too little aeration may result in black carbon forming and dropping into the fi rebox.
Burner & Pilot Operation
2
1
3