44D0060
HIGH
LOW
26D
3317
THERMOST
AT
SETTI
NG
ELECTRICAL WIRING (MILLI-VOLT)
  5.  Route wiring harnesses through large hole on side of unit. Mount bracket to side of unit with screw provided. See Figure 
22.
  6.  Attach wiring harness to either TP/TH and TH on control valve or to existing wiring harness with two (2) 0.250" male 
spade terminals for remote or t-stat option. See Figures 22 and 23.
  7.  Install knob to shaft of t-stat sensor. See Figure 22.
  8.  Place thermo bulb in front of the firebox for incoming air. 
Figure 23 - Attaching Wiring Harnesses to Control Valve 
Wiring Harnesses 
TH
TP/TH
Figure 22 - Installing T-Stat Sensor to DEB Base 
with Screw Provided  
Knob 
Thermo Bulb 
Screw
T-Stat 
Sensor and 
Bracket 