Monessen Hearth M400BFC Manual Do Utilizador

Página de 24
6
M400BFC Balanced Flue Heat-Circulating Fireplace
87D1505
D
Rise
B
G
H
B
Offset
C
E
6 FT.
G
H
A
Hearth
Floor
Chimney
Section
CHIMNEY FLUE EXIT
Elbow
FP269
MBUF
5/16/96
rev. 5/25
TCS8A 
Support
Example 1
Example 2
Example 3
Chimney Requirements - Offset Installations
Notes:   G + H cannot exceed 20 feet.
 
Air Space Clearances:  = 2” Min. to Combustibles  
Illustration Key
The following safety rules apply to 
offset installations (letters correspond 
with illustration above): 
A. Height of the chimney is measured 
from the hearth to the chimney exit.
 
   
M400BFC
Maximum:  
50’0”
Minimum:
  Without Elbows 
14’6”
  With 2 Elbows* 
14’6”
  With 4 Elbows* 
21’0”
B. Do not use more than 4 elbows per 
chimney.
Attach the straps of the return (top) 
elbow to a structural framing member.
The offset (first) elbow of any pair does 
not have straps.
FP269
C. The chimney cannot be more than 30° 
(45° in Canada) from the vertical plane in 
any installation*.
D. The maximum length of the angled run 
of the total chimney system is 20 feet. (G 
plus H cannot exceed 20 feet.)
E. A chimney support (Model TCS8A) 
is required every 6 feet of angled run of 
chimney. Chimney supports are required 
for every 30 feet and 60 feet of vertical 
chimney height above the hearth. 
Determine the offset distance of your 
chimney arrangement from the centerline 
of the fireplace to the centerline of the 
chimney where it is to pass through the 
first ceiling. 
NOTE: This offset distance may not be 
your full offset distance. See Examples 2 
and 3.
Fig. 3   Chimney system requirements.
IWF282
  0   0   0   0   0  
3”  
11”
  1   0   0   0   0  
8Z\v"  
20"
  0   1   0   0   0   11Z\v"   25Z\v"
  2   0   0   0   0   13Z\x"   29Z\v"
  1   1   0   0   0   16Z\x"   34Z\v"
  0   0   1   0   0   20Z\v"   40C\v"
  2   1   0   0   0   21C\v"   43Z\x"
  0   0   0   1   0   26Z\v"   51Z\v"
  0   1   1   0   0   28Z\x"   55Z\v"
  1   0   0   1   0   31Z\x"   60Z\v”
  0   1   0   1   0   34Z\x"   65Z\x"
  0   0   2   0   0   37Z\x"   70C\v"
  1   1   0   1   1   41Z\x"   77C\v"
  0   0   1   1   1  
45"   83C\v"
  0   1   2   0   1   47Z\v"   87Z\x"
  0   0   0   2   1  
51"  
94"
  0   1   1   1   1   53Z\v"  
98"
  0   0   3   0   1   56Z\v"   103Z\v"
  0   1   0   2   1   59Z\v"   108Z\x"
  0   0   2   1   1   62Z\v"   113Z\x"
  0   1   3   0   1   64Z\x"   117Z\x"
  0   0   1   2   1   68Z\v"  
124"
  0   1   2   1   1   70Z\x"  
128"
  0   0   0   3   1   74Z\v"   134Z\x"
  0   1   1   2   2  
78"   140C\v"
  0   0   3   1   2  
81"  
146"
  0   1   0   3   2  
84"   151Z\v"
  0   0   2   2   2  
87"   156Z\x"
  0   1   3   1   2   89Z\v"   160Z\v"
  0   0   1   3   2  
93"   166C\v"
  0   1   2   2   2   95Z\v"   170C\v"
  0   0   0   4   2   99Z\v"   177C\v"
  0   1   1   3   2  101Z\v"   181C\v"
  0   0   3   2   2  104Z\v"   186Z\v"
  0   1   0   4   2  107Z\v"   191Z\x"
  0   0   2   3   2   110Z\v"   196C\v"
  0   1   3   2   3   114"   203Z\v"
  0   0   1   4   3   117C\v"   209C\v"
  0   1   2   3   3   120"   213Z\x"
  0   0   0   5   3  123C\v"  
220" 
30˚ Elbow Offsets
1’ 1¹⁄₂' 3’ 4’
Chimney
Support
Offset
Rise
FP282
MBUF
5/26/96
Offset
Rise
30°
Return 
Elbow
30°
Return 
Elbow
30°
Offset 
Elbow
30°
Offset 
Elbow