Regency Wraps P36-LPG4 Manual Do Utilizador

Página de 44
Regency
®
 P36-4 Gas Log Fireplace
27
Option 1: 
WALL SWITCH
1)  Run supplied 15' of wire through the right 
or left side gas inlet opening. Be careful not 
to damage wire.
Note:  We recommend a maximum of 15' 
of wire but if you wish to go with a 
longer run, use the Thermostat Wire 
Table.
2)  Connect wire to supplied wall switch and 
install into the receptacle box.
CAUTION
Do not connect millivolt 
wall switch wires  for gas 
appliance to a 240V power supply.
Option 3: 
WALL THERMOSTAT 
A wall thermostat may be installed if desired, 
connect the wires as per the wiring diagram. 
Use chart below to determine the maximum 
wire length.
Note:  Preferable if the thermostat is 
installed on an interior wall.
Regency
®
 offers a programmable thermostat  
but any CSA, UCL or UL approved millivolt 
thermostat, 250-750 millivolt rated non-
anticipator type thermostat may be used.
CAUTION
Do not connect millivolt 
wall thermostat wires for 
gas appliance to a 
240V power supply.
Option 2: 
REMOTE CONTROL
Use the Regency
®
 Remote Control Kit  approved 
for this unit. Use of other systems may void 
your warranty.
The remote control kit comes with a hand held 
transmitter, a receiver and a wall mounting 
plate.
1)  Choose a convenient location on the wall 
to install the receiver and the receptacle 
box (protection from extreme heat is very 
important). Run wires from the fi replace to 
that location. Use Thermostat Wire Table.
2)  Connect the two wires to the gas valve. See 
diagram below.
CAUTION
Do not connect millivolt 
remote control wires for 
gas appliance to a 
240V power supply.
3)  Install a 9V alkaline battery in both the 
receiver and the transmitter. Install the 
receiver and its cover in the wall. Switch the 
hand held remote transmitter to "remote" 
mode. The remote control is now ready for 
operation.
Thermostat Wire Table
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
15.24 m
9.75 m
6.10 m
3.66 m
2.71 m
Recommended Maximum Lead Length 
(Two-Wire) When Using Wall 
Thermostat (CP-2 System)
Wire Size                     Max. Length
INSTALLATION